B. Michael Wroblewski
#153,780
Most Influential Person Now
B. Michael Wroblewski's AcademicInfluence.com Rankings
B. Michael Wroblewskiengineering Degrees
Engineering
#6333
World Rank
#7651
Historical Rank
Biomedical Engineering
#554
World Rank
#564
Historical Rank

B. Michael Wroblewskiphilosophy Degrees
Philosophy
#8613
World Rank
#12025
Historical Rank
Logic
#5643
World Rank
#7057
Historical Rank

Download Badge
Engineering Philosophy
B. Michael Wroblewski's Degrees
- Doctorate Medicine University of California, San Francisco
- PhD Biomedical Engineering University of California, San Francisco
Why Is B. Michael Wroblewski Influential?
(Suggest an Edit or Addition)B. Michael Wroblewski's Published Works
Number of citations in a given year to any of this author's works
Total number of citations to an author for the works they published in a given year. This highlights publication of the most important work(s) by the author
Published Works
- The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. (1988) (538)
- Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. (1998) (535)
- Questionnaire on the perceptions of patients about total hip replacement. (1996) (314)
- Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. (1996) (247)
- Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose. (2000) (225)
- Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses (2000) (204)
- Direction and rate of socket wear in Charnley low-friction arthroplasty. (1985) (176)
- Wear in Retrieved Charnley Acetabular Sockets (1996) (157)
- One-stage revision of infected total hip replacements with discharging sinuses. (1994) (126)
- Charnley low-friction arthroplasty of the hip (1993) (125)
- Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints (1985) (121)
- One‐Stage Revision of Total Hip Arthroplasty for Deep Infection (1995) (118)
- A tribological study of retrieved hip prostheses. (1992) (117)
- Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report. (2005) (116)
- Charnley low-frictional torque arthroplasty in patients under the age of 51 years. Follow-up to 33 years. (2002) (108)
- Fractured stem in total hip replacement. A clinical review of 120 cases. (1982) (105)
- Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report. (1999) (105)
- 15–21‐year Results of the Charnley Low‐friction Arthroplasty (1986) (102)
- Charnley low-frictional torque arthroplasty of the hip. 20-to-30 year results. (1999) (102)
- Long‐term Results of Low‐friction Arthroplasty in Patients 30 Years of Age or Younger (1986) (101)
- Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints: II: A microscopical study of the surfaces of Charnley polyethylene acetabular sockets (1985) (101)
- Comparison of the response of primary human peripheral blood mononuclear phagocytes from different donors to challenge with model polyethylene particles of known size and dose. (2000) (95)
- The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. (1995) (94)
- Revision of the Charnley low-friction arthroplasty for recurrent or irreducible dislocation. (1981) (92)
- Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation. (1998) (91)
- Charnley low-friction arthroplasty of the hip. Long-term results. (1993) (90)
- One‐stage Revision of Infected Cemented Total Hip Arthroplasty (1986) (89)
- Deep infection in Charnley low-friction arthroplasty. Comparison of plain and gentamicin-loaded cement. (1987) (89)
- The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets. (1997) (86)
- An Investigation into the Origins of Time-Dependent Variation in Penetration Rates with Charnley Acetabular Cups—Wear, Creep or Degradation? (1996) (84)
- Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug. (1993) (77)
- Flanged acetabular components in cemented Charnley hip arthroplasty. Ten-year follow-up of 350 patients. (1993) (75)
- Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience. (2001) (75)
- Socket design and cement pressurisation in the Charnley low-friction arthroplasty. (1988) (75)
- Wear of high-density polyethylene on bone and cartilage. (1979) (74)
- Charnley low-friction arthroplasty: 19- to 25-year results. (1992) (73)
- Charnley low-friction arthroplasty: survival patterns to 38 years. (2007) (73)
- Reattachment of the greater trochanter after hip replacement. (1985) (71)
- Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head. (1998) (68)
- Cemented revision for aseptic acetabular loosening. A review of 387 hips. (1995) (64)
- The mechanism of fracture of the femoral prosthesis in total hip replacement (1979) (64)
- Ultra-High Molecular Weight Polyethylene Wear Debris Generated in Vivo and in Laboratory Tests; the Influence of Counterface Roughness (1996) (63)
- The microbiology of infected hip arthroplasty (2006) (59)
- Revision surgery in total hip arthroplasty (1990) (58)
- External wear of the polyethylene socket in cemented total hip arthroplasty. (1987) (56)
- Wear and loosening of the socket in the Charnley low-friction arthroplasty. (1988) (55)
- Mechanical loosening of the stem in Charnley arthroplasties. Identification of the "at risk" factors. (1988) (53)
- Comparative study of the activity of total hip arthroplasty patients and normal subjects. (2001) (53)
- Charnley low-frictional torque arthroplasty: follow-up for 30 to 40 years. (2009) (51)
- Measurement of Wear in Retrieved Acetabular Sockets (1995) (51)
- Charnley low-friction arthroplasty in diabetic patients. (1983) (50)
- One stage revision arthroplasty of the hip for deep gram negative infection (1996) (49)
- The role of cement in the long term performance and premature failure of Charnley low friction arthroplasties. (1986) (49)
- Bilateral Charnley arthroplasty as a single procedure. A report on 400 patients. (1981) (47)
- The effect of cup inclination and wear on the contact mechanics and cement fixation for ultra high molecular weight polyethylene total hip replacements. (2012) (46)
- Comparison of the response of three human monocytic cell lines to challenge with polyethylene particles of known size and dose (2001) (46)
- Wear of the cup in the Charnley LFA in the young patient. (2004) (45)
- Frictional characterisation of explanted Charnley hip prostheses (1994) (45)
- Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head (1998) (45)
- Polyethylene wear from retrieved acetabular cups. (1991) (43)
- Fatal pulmonary embolism after total hip arthroplasty. Seasonal variation. (1992) (42)
- Charnley low-frictional torque arthroplasty of the hip (1999) (42)
- A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. (1997) (41)
- Intramedullary cancellous bone block to improve femoral stem fixation in Charnley low-friction arthroplasty. (1984) (41)
- Charnley low-frictional torque arthroplasty in young rheumatoid and juvenile rheumatoid arthritis: 292 hips followed for an average of 15 years (2007) (41)
- Activity and socket wear in the Charnley low-friction arthroplasty. (1994) (40)
- The effect of activity levels of total hip arthroplasty patients on socket penetration. (2001) (40)
- Revision for aseptic stem loosening using the cemented Charnley prosthesis. A review of 351 hips. (1995) (40)
- Charnley low-frictional torque arthroplasty in patients under the age of 51 years (2002) (39)
- Revision of the Acetabular Component of a Total Hip Arthroplasty with Cement in Young Patients without Rheumatoid Arthritis* (1996) (39)
- The association between rates of wear in retrieved acetabular components and the radius of the femoral head (1998) (38)
- Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles. (2000) (36)
- Charnley low-friction arthroplasty with an autograft of the femoral head for developmental dysplasia of the hip. The 10- to 15-year results. (2000) (35)
- Prevalence of impingement in explanted Charnley acetabular components (1998) (34)
- Charnley low-friction arthroplasty in patients with psoriasis. (1983) (34)
- The principle of low frictional torque in the Charnley total hip replacement. (2009) (34)
- Revision hip arthroplasty. Can the octogenarian take it? (1993) (34)
- Stem fixation in the Charnley low-friction arthroplasty in young patients using an intramedullary bone block. (1998) (33)
- Wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a 22.225 mm diameter zirconia femoral head. (2003) (32)
- The surface topography of retrieved femoral heads (1996) (31)
- Quality of the Surface Finish of the Head of the Femoral Component and the Wear Rate of the Socket in Long-Term Results of the Charnley Low-Friction Arthroplasty (1992) (31)
- Long-term results of hip arthroplasty for failure of previous surgery. (1988) (31)
- Recurrence of ectopic ossification after excision in Charnley Low Friction Arthroplasty. (1982) (30)
- Outcome of revision for mechanical stem failure using the cemented Charnley's stem. A study of 399 cases. (1996) (30)
- Surface-Active Phospholipid in Total Hip Arthroplasty (2002) (29)
- Computational assessment of the effect of polyethylene wear rate, mantle thickness, and porosity on the mechanical failure of the acetabular cement mantle (2010) (29)
- Charnley low-friction arthroplasty in teenage patients: the ultimate challenge. (2010) (29)
- Charnley low-friction arthroplasty with an autograft of the femoral head for developmental dysplasia of the hip (2000) (28)
- The friction of explanted hip prostheses. (1997) (28)
- Wear of the high-density polyethylene socket in total hip arthroplasty and its role in endosteal cavitation (1997) (27)
- Cemented Charnley revision arthroplasty for severe femoral osteolysis. (1995) (26)
- Frictional resistance of new and explanted artificial hip joints (1995) (26)
- Radiographic morphology of the osteoarthritic hip. (1982) (25)
- Salvage of failed total knee arthroplasty: the 'beefburger' procedure. (1989) (25)
- Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations (2000) (25)
- Release of gentamicin from bone cement. An ex-vivo study. (1986) (25)
- The calcar femorale in cemented stem fixation in total hip arthroplasty. (2000) (24)
- Seasonal variation in fatal pulmonary embolism after hip arthroplasty (1990) (24)
- The C-stem in clinical practice: fifteen-year follow-up of a triple tapered polished cemented stem. (2013) (24)
- A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. (2001) (23)
- Revision of failed total hip arthroplasty with a proximal femoral modular cemented stem. (2000) (23)
- Polyethylene wear in the Charnley offset bore acetabular cup. A radiological analysis. (1996) (22)
- Fatal pulmonary embolism after total hip arthroplasty: diurnal variations. (1998) (21)
- Observations of residual sub-surface shear strain in the ultrahigh molecular weight polyethylene acetabular cups of hip prostheses (1994) (21)
- Re-attachment of the un-united trochanter in Charnley low friction arthroplasty. (1989) (20)
- Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation (1998) (20)
- Cemented revision Charnley low-friction arthroplasty in patients with rheumatoid arthritis. (1994) (20)
- Treatment of fracture of the shaft of the femur in total hip arthroplasty by a combination of a Küntscher nail and a modified cemented Charnley stem. (1992) (20)
- The Charnley hip replacement -- 43 years of clinical success. (2006) (19)
- Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty. (2009) (19)
- Bulk autograft for a deficient acetabulum in Charnley low-friction arthroplasty. A 2-9-year follow-up study. (1994) (17)
- Prediction of Charnley femoral stem aseptic loosening by early post-operative radiological features (2005) (17)
- Observations on the direction of wear in Charnley sockets retrieved at revision. (1998) (16)
- Quantitative analysis of UHMWPE wear debris isolated from the periprosthetic femoral tissues from a series of Charnley total hip arthroplasties. (2002) (16)
- Effect of hip stem taper on cement stresses. (2005) (16)
- Charnley Low‐Friction Arthroplasty in the Young Patient (1992) (15)
- In-cement technique of revision hip arthroplasty. (2007) (14)
- COMPARISON OF PLAIN AND GENTAMICIN-LOADED CEMENT (1987) (14)
- Long-term results of cemented Charnley revision arthroplasty for fractured stem. (1994) (14)
- Revision surgery in total hip arthroplasty: surgical technique and results. (1982) (13)
- The natural history of debonding of the femoral component from the cement and its effect on long-term survival of Charnley total hip replacements. (1999) (13)
- Charnley low-friction arthroplasty for the treatment of hips with late complications of femoral neck fractures. (1984) (12)
- Wear and fracture of the acetabular cup in Charnley low-friction arthroplasty. (1998) (12)
- POLYETHYLENE WEAR IN THE CHARNLEY OFFSET BORE ACETABULAR CUP (1996) (12)
- A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene. (1999) (12)
- Current trends in revision of total hip arthroplasty (2004) (12)
- Charnley low frictional torque arthroplasty: clinical developments. (2005) (11)
- The calcar femorale in cemented stem fixation in total hip arthroplasty (2000) (11)
- Cementless versus cemented total hip arthroplasty. A scientific controversy? (1993) (10)
- Outcome of Charnley total hip replacement across a single health region in England. (2000) (10)
- Revision of failed total hip arthroplasty with a proximal femoral modular cemented stem (2000) (10)
- Periprosthetic Femoral Fractures Treated with a Modular Distally Cemented Stem (2007) (9)
- Charnley low-frictional torque arthroplasty for avascular necrosis of the femoral head. (2005) (9)
- Increasing patients' body mass. Are the criteria for testing stemmed femoral components in total hip arthroplasty still valid? (2007) (9)
- Charnley low-friction arthroplasty. Review of the past, present status, and prospects for the future. (1986) (9)
- Observations on the direction of wear in Charnley sockets retrieved at revision (1998) (9)
- Factors affecting socket fixation after cemented revision (1997) (9)
- Fatal pulmonary embolism and mortality after revision of failed total hip arthroplasties. (2000) (8)
- The premature failure of the Charnley Elite-Plus stem. (2006) (8)
- Stem fixation in the Charnley low-friction arthroplasty in young patients using an intramedullary bone block (1998) (8)
- The angle-bore acetabular component and dislocation after revision of a failed total hip replacement. (2006) (8)
- Blood loss and operation time in the Charnley low friction arthroplasty. (1981) (8)
- Discrepancy between penetration depths derived from radiographic and direct measurement of acetabular components (1998) (8)
- Determination of the trabecular bone direction from digitised radiographs. (2003) (8)
- A 28‐year clinical and radiological follow‐up of alumina ceramic‐on‐crosslinked polyethylene total hip arthroplasty: A FOLLOW‐UP REPORT AND ANALYSIS OF THE OXIDATION OF A SHELF‐AGED ACETABULAR COMPONENT (2017) (7)
- A sinister bias in hip socket wear: brief report. (1989) (7)
- Differences in the rates of penetration determined from radiographic and shadowgraphic measurements of acetabular sockets. (1998) (7)
- Osteolysis due to particle wear debris following total hip arthroplasty: the role of high-density polyethylene. (1994) (6)
- Transverse load on the hip joint: a subject for further research (1980) (6)
- Source of the cement within the Charnley hip. (1990) (6)
- Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. (1991) (6)
- Multiple revision for failed Charnley low-friction arthroplasty. (1995) (5)
- Microseparation, fluid pressure and flow in failures of metal-on-metal hip resurfacing arthroplasties (2012) (5)
- Girdlestone Pseudarthrosis for a Failed Total Hip Arthroplasty (1990) (5)
- SURVIVAL PATTERNS TO 38 YEARS (2007) (5)
- LOW-FRICTION ARTHROPLASTY OF THE HIP USING ALUMINA CERAMIC AND CROSS-LINKED POLYETHYLENE. A SEVENTEEN YEAR FOLLOW-UP STUDY. (2006) (5)
- Psoas tenotomy and heterotopic ossification after Charnley low-friction arthroplasty. (1993) (5)
- Analysis of debris from brushing the femoral canal with a plastic brush—a potential cause of loosening in total hip replacement (1999) (4)
- Discrepancy in the length of the tibiae in unilateral congenital dislocation of the hip. (1999) (4)
- Structural changes in the socket of a charnley low friction arthroplasty associated with recurrent subluxation (2004) (4)
- Fracture of the Shaft of the Femur (1990) (4)
- THE MECHANICAL PROPERTIES OF MODERN ADDITIONAL ANTIBIOTICS IN ACRYLIC BONE CEMENT (2002) (4)
- Incidence of loose bodies in an osteoarthritic hip. (2001) (3)
- iii) The infected total hip replacement (2000) (3)
- Pain in osteoarthrosis of the hip. (1978) (3)
- Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. (2000) (3)
- REDUCED DIAMETER OF THE NECK AND ITS EFFECT ON THE INCIDENCE OF ASEPTIC CUP LOOSENING IN THE CHARNLEY LFA (2005) (3)
- Fracture of the Stem (1990) (2)
- CHARNLEY LOW FRICTIONAL TORQUE ARTHROPLASTY IN THE YOUNG PATIENT. FACTORS AFFECTING OUTCOME. (2003) (2)
- Femoral head autograft and contralateral total hip arthroplasty. (1993) (2)
- Osteoarthritis of the hip secondary to congenital dysplasia. (1979) (2)
- Intramedullary Cancellous Bone Block (2016) (2)
- TRIPLE TAPERED POLISHED CEMENTED STEM (C-STEM) IN TOTAL HIP ARTHROPLASTY. FOLLOW-UP TO 10 YEARS. (2006) (1)
- Total hip arthroplasty: results and consequences. (2004) (1)
- Laterality of hip pain (1993) (1)
- SEVERE FEMORAL OSTEOLYSIS TREATED WITH A CEMENTED CHARNLEY REVISION ARTHROPLASTY. CLINICAL AND RADIOLOGICAL FOLLOW-UP TO 27 YEARS (2015) (1)
- Quality of the Surface Finish of the Head of the Femoral Component and the Wear Rate of the Socket in Long-Term Results of the Charnley Low-Friction Arthroplasty (1992) (1)
- Socket Size and the Expected Quality of its Fixation in the Cemented Total Hip Arthroplasty (1990) (1)
- Short Stem in Charnley Low-Friction Arthroplasty—A Review of 100 Cases (1991) (1)
- ONE STAGE REVISION OF INFECTED TOTAL HIP ARTHROPLASTY IN THE PRESENCE OF A DISCHARGING SINUS (1995) (1)
- Long-Term Outcome after Charnley Low Frictional Torque Arthroplasty (2005) (1)
- Migrating Wear Marker in the Charnley Low Friction Arthroplasty (1991) (1)
- Penetration of UHMWPE Cup: Wear or Creep (2016) (1)
- Hip socket impingement. (1993) (1)
- REVISION TOTAL HIP REPLACEMENT FOR RECURRENT DISLOCATION BY A SINGLE SURGEON (2005) (0)
- ACETABULAR REVISION USING FREEZE-DRIED ALLOGRAFTS (2004) (0)
- Factors Affecting Socket Fixation In Charnley Low Friction Arthroplasty (2001) (0)
- Post-operative Length of Hospital Stay (2016) (0)
- Comparison of Direct and Radiographic Wear Measurements (2016) (0)
- POST OPERATIVE PYREXIA AND PRIMARY HIP ARTHROPLASTY (2003) (0)
- Patterns of Failure of Stem Fixation (2016) (0)
- Design of Components, Range of Movement. Impingement, Dislocation (2016) (0)
- Loosening of the Components (1990) (0)
- The Concept of Total Hip Arthroplasty: The Beginning (2016) (0)
- BONE STOCK AND CEMENT-BONE INTERFACE IN REVISION TOTAL HIP REPLACEMENT FOR DEEP INFECTION (2008) (0)
- Revision for Recurrent or Irreducible Dislocation (2016) (0)
- Tissue Reaction to High-Density Polyethylene Wear Particles (1990) (0)
- Wear of the UHMWPE Cup, Tissue Reaction to Wear Particles, Endosteal Cavitation and Component Loosening. Is the Problem Mechanical or Biological? (2016) (0)
- Radiographic Assessment of the Osteoarthritic Hip (2016) (0)
- Position of the Stem Within the Medullary Canal (2016) (0)
- Data in clinical studies of volumetric wear rates. (2001) (0)
- 2 – Hip replacements (2008) (0)
- Loosening of the Socket (1990) (0)
- BONE STOCK AND CEMENT-BONE INTERFACE IN ONE STAGE REVISION TOTAL HIP REPLACEMENT FOR DEEP INFECTION: THE IMPORTANCE OF SHIELDING MEDULLARY SPACE WITH ANTIBIOTIC-LOADED CEMENT (2005) (0)
- Stem Design and Fixation (2016) (0)
- Triple tapered polished cemented stem: the C-stem in total hip arthroplasty with a minimum follow-up of 10 years (2011) (0)
- A New Surgical Science (2016) (0)
- The Metal/Polyethylene Interface (2000) (0)
- Failure patterns after total hip arthroplasty. (1983) (0)
- CHARNLEY LFA WITH FEMORAL HEAD AUTOGRAFT FOR DEVELOPMENTAL DYSPLASIA OF THE HIP. 15–21 YEAR RESULTS: A FOLLOW-UP NOTE (2006) (0)
- CHARNLEY LOW-FRICTIONAL TORQUE ARTHROPLASTY SURVIVORSHIP PATTERNS: FOLLOW-UP TO 38 YEARS. (2009) (0)
- Arthroplasty of the Hip: A New Operation (2016) (0)
- PRIMARY TOTAL HIP ARTHROPLASTY IN YOUNG PATIENTS USING A CEMENTED TRIPLE TAPERED POLISHED FEMORAL COMPONENT. FOLLOW-UP TO 20 YEARS (2016) (0)
- Changing Patterns of Patients Presenting for the Operation (2016) (0)
- The clinical and radiological results of revision of low friction arthroplasty in the elderly (2004) (0)
- Wear of UHMWPE Cup and Consequences (2016) (0)
- Factors Affecting Wear. Patient Activity Level (2016) (0)
- The Effect of Cup Inclination on Contact Mechanics (2016) (0)
- Management of Deep Infection (2016) (0)
- REVISION OF PERIPROSTHETIC FRACTURES AFTER TOTAL HIP REPLACEMENT USING A PROXIMAL FEMORAL REPLACEMENT MODULAR CEMENTED STEM (2010) (0)
- Contamination of the Visors of Total Body Exhaust Suits in Total Hip Replacement Surgery (2004) (0)
- Bacteriological swabs in hip surgery. (1983) (0)
- Pulmonary Embolism After Total Hip Arthroplasty (2016) (0)
- CEMENTED SOCKET REVISION-FACTORS INFLUENCING ITS SUCCESS (1995) (0)
- Exposure of the Hip - Trochanteric Osteotomy, Re-Attachment and Results (2014) (0)
- CEMENTED HIP REVISION FOR ASEPTIC CUP LOOSENING USING STRUCTURAL ACETABULAR ALLOGRAFT. CLINICAL AND RADIOLOGICAL FOLLOW-UP TO 22 YEARS (2016) (0)
- Loosening of Components (2016) (0)
- [Loosening of hip prostheses]. (1989) (0)
- Wear of the UHMWPE Cup (2016) (0)
- O1153 THE PARADOX OF POST-OPERATIVE PYREXIA AND DEEP INFECTION FOLLOWING HIP ARTHROPLASTY (2004) (0)
- Tribological characterisation of explanted charnley hip prostheses (1994) (0)
- Results of Low-Friction Arthroplasty of the Hip Performed as a Primary Intervention (2016) (0)
- ALUMINA CERAMIC – CROSS LINKED POLYETHYLENE ARTICULATION IN THE CHARNLEY LOW-FRICTION ARTHROPLASTY (10 YEAR RESULTS). (2003) (0)
- The Socket: Changes at the Bone—Cement Interface (1990) (0)
- THE MICROBIOLOGY OF THE INFECTED TOTAL HIP REPLACEMENT (2003) (0)
- Loosening of the Stem (2016) (0)
- Exposure of the Hip Joint (2016) (0)
- PREOPERATIVE BONE STOCK AND CEMENT-BONE INTERFACE (SHIELDING OF MEDULLARY SPACE) IN REVISION TOTAL HIP REPLACEMENT FOR DEEP INFECTION (2006) (0)
- Revision with Trochanteric Non-union: Reattachment of the Un-united Trochanter (1990) (0)
- Deep Infection: The Role of Acrylic Cement (2016) (0)
- The Reasons for Follow-Up (2016) (0)
- CHARNLEY LOW FRICTIONAL TORQUE ARTHROPLASTY. FOLLOW-UP OVER THIRTY YEARS (2005) (0)
- Comprar Charnley Low-Frictional Torque Arthroplasty Of The Hip. Practice And Results | B.M. Wroblewski | 9783319213194 | Springer (2016) (0)
- Range of motion of the hip. (2000) (0)
- Bone-Cement Interface: The Cup: Radiographic Appearances (2016) (0)
- Wear of the Cup. 22.225 mm Alumina Ceramic Head, Charnley Femoral Component and Cross-Linked Polyethylene Cup (2016) (0)
- Instrument Tray System (2016) (0)
- Loss of Bone Stock (1990) (0)
- Increasing Follow-Up: Changing Age Patterns (2016) (0)
- Fashioning a new greater trochanter for unusual Charnley low friction arthroplasties. (1980) (0)
- FACTORS AFFECTING THE OUTCOME OF SOCKET FIXATION AFTER REVISION WITH BONE GRAFTING (2006) (0)
- Wear of the Socket (1990) (0)
- Metal Backing of the Socket (1990) (0)
- The Principle of Low Frictional Torque in Clinical Practice (2016) (0)
- Contamination of the visors of total body exhaust suits in total hip replacement surgery. (2004) (0)
- LEG LENGTHENING AFTER TOTAL HIP ARTHROPLASTY. IDENTIFICATION OF PATIENTS AT RISK. (2016) (0)
- Patterns of Failure and Revisions: Guidelines for Follow-Up (2016) (0)
- The Charnley Acetabular Cup (2016) (0)
- MEDIUM TERM RESULTS OF CHARNLEY LOW OFFSET STEM (2004) (0)
- TRIPLE TAPERED CEMENTED C-STEM. A MINIMUM 10 YEAR FOLLOW UP (2009) (0)
- Improving Design and Surgical Technique Reducing the Incidence of Component Loosening (2016) (0)
- HIGH WEAR V LOW WEAR OF THE CUP IN CHARNLEY LFA IN PATIENTS UNDER THE AGE OF 51 YEARS (2004) (0)
- Charnley Low-friction Arthroplasty (2006) (0)
- Factors Affecting Wear of the UHMWPE Cup (2016) (0)
- THE CUP OUTER DIAMETER INFLUENCES THE CEMENT FIXATION OF CHARNLEY TOTAL HIP REPLACEMENT (2012) (0)
- DISLOCATION AFTER REVISION OF 1039 FAILED TOTAL HIP ARTHROPLASTIES. (22.225 MM DIAMETER HEAD AND AN ANGLE-BORE CUP). (2006) (0)
This paper list is powered by the following services: