Frank Herbert Attix
#141,703
Most Influential Person Now
Frank Herbert Attix's AcademicInfluence.com Rankings
Frank Herbert Attixmedical Degrees
Medical
#2576
World Rank
#3005
Historical Rank
Radiology
#50
World Rank
#60
Historical Rank

Download Badge
Medical Physics
Why Is Frank Herbert Attix Influential?
(Suggest an Edit or Addition)Frank Herbert Attix's Published Works
Number of citations in a given year to any of this author's works
Total number of citations to an author for the works they published in a given year. This highlights publication of the most important work(s) by the author
Published Works
- Introduction to Radiological Physics and Radiation Dosimetry (1991) (1665)
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. (1992) (433)
- Introduction to Radiological Physics and Radiation Dosimetry: Attix/Introduction (2007) (429)
- Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. (1992) (358)
- A theory of cavity ionization. (1955) (290)
- Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams (1992) (215)
- A solid water phantom material for radiotherapy x‐ray and γ‐ray beam calibrations (1982) (204)
- Calibration of 192Ir high-dose-rate afterloading systems. (1991) (161)
- 5 – Monte Carlo Techniques of Electron and Photon Transport for Radiation Dosimetry (1990) (158)
- The Dosimetry of Ionizing Radiation (1986) (121)
- Further consideration of the track-interaction model for thermoluminescence in LiF(TLD-100) (1975) (93)
- Composition of A-150 tissue-equivalent plastic. (1977) (90)
- The calibration and use of plane-parallel ionization chambers for dosimetry of electron beams: an extension of the 1983 AAPM protocol report of AAPM Radiation Therapy Committee Task Group No. 39. (1994) (80)
- A solid water phantom material for radiotherapy x-ray and gamma-ray beam calibrations. (1982) (73)
- The Dosimetry of Ionizing Radiation, Vol. 2 (1987) (71)
- Topics in radiation dosimetry (1972) (56)
- The use of 10B to enhance the tumour dose in fast-neutron therapy. (1978) (51)
- The partition of kerma to account for bremsstrahlung. (1979) (48)
- Protocol for Neutron Beam Dosimetry (1980) (46)
- Thermoluminescence and Color Centers in LiF:Mg (1967) (44)
- Comparison of Burlin cavity theory with LiF TLD measurements for cobalt-60 gamma rays. (1980) (43)
- Design of free-air ionization chambers (1957) (42)
- Mass energy-transfer and mass energy-absorption coefficients, including in-flight positron annihilation for photon energies 1 keV to 100 MeV (1991) (42)
- DAMAGE EFFECTS IN CAF2:MN AND LIF THERMOLUMINESCENT DOSIMETERS. (1964) (40)
- New Thermoluminescent Dosimeter (1960) (39)
- LiF and CaF2:Mn thermoluminescent dosimeters in tandem. (1968) (38)
- A new re-entrant ionization chamber for the calibration of iridium-192 high dose rate sources. (1992) (36)
- A determination of the gamma-ray emission of radium (1957) (34)
- Lithium fluoride glow-peak growth due to annealing. (1972) (34)
- CAVITY IONIZATION AS A FUNCTION OF WALL MATERIAL (1958) (30)
- Determination of Aion and Pion in the new AAPM radiotherapy dosimetry protocol. (1984) (30)
- THERMAL QUENCHING OF LUMINESCENCE IN SIX THERMOLUMINESCENT DOSIMETRY PHOSPHORS. II. QUENCHING OF THERMOLUMINESCENCE. (1969) (30)
- Temperature stability of CaF2:Mn and LiF(TLD-100) thermoluminescent dosimeters. (1967) (26)
- 1 – BASIC CONCEPTS OF DOSIMETRY (1968) (25)
- Thermoluminescent dosimeters for high-dose applications. (1973) (24)
- Electron contamination in 60 Co gamma-ray beams. (1983) (23)
- Radiobiological studies with cyclotron-produced neutrons currently used for radiotherapy. (1975) (22)
- Neutron beam dosimetry at the NRL Cyclotron. (1973) (22)
- A simple derivation of Ngas, a correction in Awall, and other comments on the AAPM Task Group 21 protocol. (1984) (20)
- Anomalous fading of CaF2:Mn thermoluminescent dosimeters (1969) (18)
- Thermal quenching of luminescence in six thermoluminescent dosimetry phosphors—I: Quenching of X-ray-excited radioluminescence (1969) (16)
- Plate separation requirements for standard free-air ionization chambers. (1954) (16)
- Energy imparted, energy transferred and net energy transferred. (1983) (16)
- Uncertainty of calibrations at the accredited dosimetry calibration laboratories. (1997) (16)
- A proposal for the calibration of plane-parallel ion chambers by accredited dosimetry calibration laboratories. (1990) (15)
- Application of a commercial solid-water plane-parallel ionization chamber to the AAPM TG-21 protocol. (1993) (15)
- Academic Program for Master of Science Degree in Medical Physics (1993) (14)
- Displacement correction factor for fast-neutron dosimetry in a tissue-equivalent phantom. (1976) (13)
- RADIOPHOTOLUMINESCENCE DOSIMETRY SYSTEM OF THE U.S. NAVY (1953) (12)
- Spatial distribution of human cell survival in a neutron beam designed for therapy (1974) (12)
- Stripping-theory analysis of thick-target neutron production for D + Be. (1976) (12)
- An ionization chamber for kilocurie source calibrations. (1962) (11)
- A cavity ionization theory including the effects of energetic secondary electrons. (1955) (11)
- Energy-absorption coefficients for γ-rays in compounds or mixtures (1984) (11)
- Gamma‐ and X‐Ray Interactions in Matter (2007) (11)
- Fast neutron dose rate as a function of incident deuteron energy for D+9Be. (1973) (11)
- Energy imparted, energy transferred, and net energy transferred (1983) (11)
- Calculational methods for estimating skin dose from electrons in Co-60 gamma-ray beams. (1983) (10)
- Fast‐neutron dosimetry using F centers in MgO (1973) (9)
- An intercomparison of the roentgen standards of Great Britain and U.S.A. (1956) (9)
- ELECTRONIC EQUILIBRIUM IN FREE-AIR CHAMBERS AND A PROPOSED NEW CHAMBER DESIGN (1961) (9)
- The meanings of "first collision dose". (1966) (8)
- The physics and dosimetry of fast neutrons for radiotherapy. Memorandum report. [Secondary protons] (1975) (8)
- Plate-separation requirements for standard free-air ionization chambers (1954) (8)
- Comparison of Monte Carlo and analytical calculations of average dose deposited in aluminum foils by broad beams of electrons (1991) (7)
- Charge storage in electron-irradiated phantom materials. (1986) (7)
- A comparison of methods for calibrating parallel-plate chambers/. (1994) (7)
- Attenuation measurements of a fast neutron radiotherapy beam. (1976) (6)
- RADIATION DOSIMETRY. VOLUME III. SOURCES, FIELDS, MEASUREMENTS, AND APPLICATIONS. Second Edition. (1969) (6)
- Ionisation error due to porosity in graphite ionisation chambers. (1980) (6)
- THERMOLUMINESCENCE PROCESSES AND COLOR CENTERS IN LiF:Mg. (1969) (6)
- Quantities for Describing the Interaction of Ionizing Radiation with Matter (2007) (6)
- Thermal quenching of luminescence in six thermoluminescent dosimetry phosphors—II (1969) (5)
- Scattered radiation from a neutron collimator. (1977) (5)
- Mass Energy Transfer and Absorption Coefficients, Including In-Flight Positron Annihilation (1992) (5)
- Comparison of the Bragg-Gray theory corollaries to fast-neutron cavity ionization measurements at 14.8 MeV. (1980) (5)
- The calibration and use of plane-parallel ionization chambers for dosimetry of electron beams: An extension of the 1983 AAPM protocol report of AAPM Radiation Therapy Committee Task Group (2002) (5)
- The Effects of Air Humidity on Ionisation Chamber Response (1987) (5)
- Presentation of nominal accelerating potential as a function of the ionization ratio in the new AAPM dosimetry protocol (1984) (4)
- Charged‐Particle Interactions in Matter (2007) (4)
- Equations for Ngas and Nair in terms of Nx and Nk. (1989) (3)
- Neutron Interactions and Dosimetry (2007) (3)
- A shielding maze at a neutron radiotherapy facility. (1976) (3)
- A SOLID STATE BRAGG-GRAY CAVITY CHAMBER (1960) (3)
- Topics of general interest, session II (1977) (3)
- A proportional counter for thermally- stimulated exoelectrons (1971) (3)
- Performance characteristics of A 150 plastic-equivalent gases in A 150 plastic proportional counters for 14.8-MeV neutrons. (1984) (3)
- RADIATION-INDUCED OPTICAL ABSORPTION AND PHOTOLUMINESCENCE OF LiF POWDER FOR HIGH-LEVEL DOSIMETRY. (1971) (3)
- Sources, fields, measurements, and applications (1969) (3)
- Characteristics of A-150 plastic-equivalent gas in A-150 plastic ionization chambers for p(66)Be(49) neutrons. (1982) (3)
- Computed Values of the Specific γ-Ray Constant T for 137Cs and 60Co (1968) (3)
- Basic gamma-ray dosimetry. (1968) (3)
- Application of A150 plastic-equivalent gas in A150 plastic ionization chambers for Co-60 gamma rays and 14.8-MeV neutrons. (1982) (2)
- Diffuse Reflectance and Fluorescence Measuring Apparatus (1971) (2)
- Radioactivation of iron and Benelex by the fast neutrons generated by 35-MeV deuterons in a Be target. (1978) (2)
- DOSIMETRY BY SOLID STATE DEVICES (1962) (2)
- Fractional neutron KERMA for hydrogen, carbon, nitrogen, and oxygen deduced from microdosimetric measurements (1982) (2)
- A method for matching NBS x-ray beam qualities with a half- or full-wave rectified generator. (1985) (2)
- Electron contamination in 60Co gamma-ray beams. (1983) (2)
- METHOD FOR MOUNTING POWDERED THERMOLUMINESCENT SAMPLES WITH IMPROVED THERMAL CONTACT. (1967) (2)
- Radiation Dosimetry: Physical and Biological Aspects edited by C. G. Orton (1986) (2)
- Isotopic effect in lithium fluoride thermoluminescent dosemeters. (1969) (1)
- Fast neutron dosimetry. Progress report, July 1, 1978-June 30, 1979. Wisconsin Medical Physics report No. WMP-109 (1979) (1)
- The energy dependence of CaF/sub 2/:Mn/Teflon thermoluminescent dosimeters (1990) (1)
- PILOT COMPARISON OF TWO THERMOLUMINESCENT DOSIMETRY SYSTEMS WITH FILM BADGES IN ROUTINE PERSONNEL MONITORING (1968) (1)
- THERMOLUMINESCENT DOSIMETERS FOR PERSONNEL MONITORING. (1968) (1)
- An Intercomparison of the Roentgen Standards of Great Britain and U. S. A. (1956) (1)
- Ion chamber volume versus humidity. (1983) (1)
- Something Old, Something New, Something Basic (1993) (1)
- A current look at TLD in personnel monitoring. (1972) (1)
- References to Unpublished Reports (1965) (1)
- Experimental derivation of β for high-energy photons (1988) (1)
- LUMINESCENCE AND EXOELECTRON DOSIMETRY IN PERSONNEL MONITORING. (1971) (1)
- Skin-sparing effects of neutron beam filtering materials. (1987) (1)
- Charged‐Particle and Radiation Equilibria (2007) (1)
- A device for loading thermoluminescent dosimetry powder into capsules. (1973) (1)
- A device for loading powder into capsules thermoluminescent dosimetry (1973) (1)
- Applicability of paired graphite and A150 plastic proportional counters to neutron- and photon-dose determinations (1981) (1)
- Must personnel dosimeters also serve as gamma-ray energy spectrometers? (1967) (1)
- Use of Miniature Glass-Needle-Type TL Dosimeters in Finger-Ring Applications. (1971) (1)
- Measurement of dose components in an n-$gamma$ field (1974) (1)
- AUTOMATIC TIMER SIMPLIFIES SMALL-CURRENT MEASUREMENTS (1957) (1)
- Report on NRL Measurements as a Participant in the INDI. (1975) (1)
- METHODS FOR CURRENT MEASUREMENT WITH A VIBRATING REED ELECTROMETER (1952) (1)
- Neutron dosimetry for the MANTA facility at NRL. (1974) (1)
- CURRENT LOOK AT THERMOLUMINESCENT DOSIMETRY (TLD) IN PERSONNEL MONITORING. (1972) (0)
- Application of thermoluminescent dosimeters for measurement of mixed neutron-gamma beams (1974) (0)
- Review of radiation dosimetry research at the University of Wisconsin during 1961-1982 (1982) (0)
- Radiobiology with the neutron beam at the NRL cyclotron (1974) (0)
- The Dosimetry of Ionizing Radiation, Vol. III. Kenneth R. Kase , Bengt E. Bjärngard , Frank H. Attix (1991) (0)
- THERMOLUMINESCENT DOSIMETERS ON RECOVERABLE SATELLITES (1963) (0)
- X‐Ray Production and Quality (2007) (0)
- ENERGY DEPENDENCE AND DIRECTIONAL DEPENDENCE OF THE DT-60 SILVER PHOSPHATE GLASS DOSIMETER (1952) (0)
- Use of LiF-Teflon discs in laminated identification cards for personnel accident dosimetry. (1971) (0)
- Guard Ring Shielding to Eliminate Instability of Collecting Volume in Ionization Chambers (1968) (0)
- SPURIOUS THERMOLUMINESCENCE OF CaF$sub 2$:Mn AND LiF(TLD-100). (1967) (0)
- A constant-power circuit for heating thermoluminescent dosimeters. (1967) (0)
- THERMOLUMINESCENT DOSIMETERS OF LITHIUM BORATE. (1968) (0)
- Preliminary study of a gamma-ray telescope relevant to neutron personnel dosimetry (1980) (0)
- Clarification of the concept of "emitted radiation". (1980) (0)
- Revised neutron/gamma dose estimates in a water phantom for 14. 8-MeV neutrons (1981) (0)
- Dosimetry by Pulse‐Mode Detectors (2007) (0)
- Fast neutron dosimetry. Progress report, July 1, 1979-June 30, 1980 (1980) (0)
- Anti W comparisons for A150 plastic-equivalent gases, TE gas, and air (1981) (0)
- THE ENERGY DEPENDENCE OF C~F~:MI~EF%ON THERMOLUMINESCENT DOSIMETERS (1990) (0)
- APPLICATION OF AlSO-PLASTIC EQUIVALENT GASES IN MICRODOSIMETRIC MF.ASURF.MENTS* (2013) (0)
- Luminescence Dosimetry. (1965) (0)
- An adiabatic calorimeter for measuring x-ray dose in silicon. (1973) (0)
- Dosimetry and Callbration of Photon and Electron Beams with Cavity Ion Chambers (2007) (0)
- Progress overview, July 1, 1980-September 30, 1981 (1981) (0)
- DESIGN OF FREE-AIR IONIZATION CHAMBERS Handbook 64 United States Department of Commerce (2017) (0)
- VARIATION OF ELECTRON-INDUCED RADIOLUMINESCENCE IN LITHIUM FLUORIDE AS A FUNCTION OF TOTAL DOSE. (1969) (0)
- Application of A150-plastic equivalent gases in microdosimetric measurements (1981) (0)
- Plate-Separation Requirements for Standard Ionization Chambers 1 Free-Air (2011) (0)
- Neutron-beam dosimetry control system (1974) (0)
- Enhanced from low-energy bremstrahlung following high-/low-Z interfaces (1974) (0)
- The MANTA neutron-therapy facility at the Naval Research Laboratory. (1974) (0)
- Experimental derivation of beta for high-energy photons. (1988) (0)
- Microdosimetry with the NRL cancer therapy fast-neutron beam (1974) (0)
- Response of a. gamma. -ray ''telescope'' dosimeter to the (n +. gamma. ) radiation from a /sup 239/Pu-Be source (1985) (0)
- Comparison of neutron/gamma dose estimates: ion-chamber measurements vs. Monte Carlo calculations (1983) (0)
- Low‐Energy Photon Dose Deposition in Tissue Slab and Spherical Phantoms (1984) (0)
- Performance of an Improved Methane-Flow Proportional Counter for TSEE. (1974) (0)
- Design criteria for a hemispherical detector for LET measurements (1980) (0)
- Absorbed Dose in Radioactive Media (2007) (0)
- Erratum: Dosimetry intercomparisons between fast‐neutron radiotherapy facilities [Med. Phys. 2, 195 (1975)] (1976) (0)
- Fast-neutron dosimetry. Progress report, 1 July 1982-30 June 1983 (1983) (0)
- Review of radiological physics, dosimetry and biology research at the University of Wisconsin during 1961-1984 (1984) (0)
This paper list is powered by the following services: