Georg Bergmann
#165,699
Most Influential Person Now
Researcher
Georg Bergmann's AcademicInfluence.com Rankings
Download Badge
Physics
Why Is Georg Bergmann Influential?
(Suggest an Edit or Addition)Georg Bergmann's Published Works
Number of citations in a given year to any of this author's works
Total number of citations to an author for the works they published in a given year. This highlights publication of the most important work(s) by the author
Published Works
- Hip contact forces and gait patterns from routine activities. (2001) (2032)
- Hip joint loading during walking and running, measured in two patients. (1993) (1247)
- Loading of the knee joint during activities of daily living measured in vivo in five subjects. (2010) (667)
- Duration and frequency of every day activities in total hip patients. (2001) (363)
- Tibio‐femoral loading during human gait and stair climbing (2004) (362)
- Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method. (2006) (358)
- Musculo-skeletal loading conditions at the hip during walking and stair climbing. (2001) (350)
- Determination of muscle loading at the hip joint for use in pre-clinical testing. (2005) (326)
- Standardized Loads Acting in Hip Implants (2014) (311)
- Realistic loads for testing hip implants. (2010) (254)
- Influence of a Follower Load on Intradiscal Pressure and Intersegmental Rotation of the Lumbar Spine (2001) (254)
- Standardized Loads Acting in Knee Implants (2014) (253)
- In vivo glenohumeral contact forces--measurements in the first patient 7 months postoperatively. (2007) (216)
- Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis (2007) (200)
- ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months. (2009) (196)
- Hip joint contact forces during stumbling (2004) (193)
- Knee Adduction Moment and Medial Contact Force – Facts about Their Correlation during Gait (2013) (186)
- Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb. (2003) (171)
- Applying a follower load delivers realistic results for simulating standing. (2009) (166)
- Is staircase walking a risk for the fixation of hip implants? (1995) (166)
- Determination of trunk muscle forces for flexion and extension by using a validated finite element model of the lumbar spine and measured in vivo data. (2006) (165)
- Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants (2007) (165)
- Influence of graded facetectomy and laminectomy on spinal biomechanics (2003) (162)
- Estimation of muscle forces in the lumbar spine during upper-body inclination. (2001) (151)
- Loads on an internal spinal fixation device during walking. (1997) (148)
- In vivo measurement of shoulder joint loads during activities of daily living. (2009) (144)
- Finite-element-analysis and experimental investigation in a femur with hip endoprosthesis. (1983) (138)
- Frictional heating of total hip implants. Part 1: measurements in patients. (2001) (133)
- Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplasty (2006) (132)
- Multichannel strain gauge telemetry for orthopaedic implants. (1988) (132)
- A comparison of hip joint forces in sheep, dog and man. (1984) (130)
- Monitoring In Vivo Implant Loads With a Telemeterized Internal Spinal Fixation Device (2000) (126)
- Realistic loading conditions for upper body bending. (2009) (126)
- In vivo gleno-humeral joint loads during forward flexion and abduction. (2011) (125)
- Influence of limb alignment on mediolateral loading in total knee replacement: in vivo measurements in five patients. (2012) (124)
- Is It Possible to Simulate Physiologic Loading Conditions by Applying Pure Moments?: A Comparison of In Vivo and In Vitro Load Components in an Internal Fixator (2001) (124)
- Validation of the Delft Shoulder and Elbow Model using in-vivo glenohumeral joint contact forces. (2010) (123)
- Influence of shoes and heel strike on the loading of the hip joint. (1995) (119)
- Design, calibration and pre-clinical testing of an instrumented tibial tray. (2007) (117)
- Effect of Total Disc Replacement with ProDisc on Intersegmental Rotation of the Lumbar Spine (2005) (117)
- Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients. (2001) (115)
- Influence of different artificial disc kinematics on spine biomechanics. (2009) (107)
- ISSLS Prize Winner: A Novel Approach to Determine Trunk Muscle Forces During Flexion and Extension: A Comparison of Data From an In Vitro Experiment and In Vivo Measurements (2003) (106)
- Finite-element-analysis and experimental investigation of stresses in a femur. (1982) (100)
- Hip endoprosthesis for in vivo measurement of joint force and temperature. (1999) (99)
- The effect of valgus braces on medial compartment load of the knee joint - in vivo load measurements in three subjects. (2011) (99)
- Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises (2001) (95)
- Total hip joint prosthesis for in vivo measurement of forces and moments. (2010) (93)
- Hip Joint Forces During Load Carrying (1997) (85)
- Loads on internal spinal fixators measured in different body positions (1999) (85)
- Patellofemoral joint contact forces during activities with high knee flexion (2012) (84)
- Effect of an artificial disc on lumbar spine biomechanics: a probabilistic finite element study (2008) (84)
- Material properties of femoral cancellous bone in axial loading (2004) (82)
- Frictional heating of total hip implants. Part 2: finite element study. (2001) (78)
- Loads on a Telemeterized Vertebral Body Replacement Measured in Two Patients (2008) (77)
- A spinal fixation device for in vivo load measurement. (1994) (75)
- Modulation of the Relationship Between External Knee Adduction Moments and Medial Joint Contact Forces Across Subjects and Activities (2014) (74)
- Activities of Everyday Life with High Spinal Loads (2014) (74)
- Influence of ligament stiffness on the mechanical behavior of a functional spinal unit. (2004) (74)
- Effect of a posterior dynamic implant adjacent to a rigid spinal fixator. (2006) (72)
- Four-channel telemetry system for in vivo measurement of hip joint forces. (1991) (72)
- Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month. (2008) (71)
- An EMG-driven musculoskeletal model of the shoulder. (2012) (71)
- An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint. (2009) (70)
- Friction in Total Hip Joint Prosthesis Measured In Vivo during Walking (2013) (69)
- Implantable Sensor Technology: From Research to Clinical Practice (2012) (68)
- A comprehensive assessment of the musculoskeletal system: The CAMS-Knee data set. (2017) (67)
- An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column. (2007) (67)
- Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices. (1999) (67)
- Hip joint forces in sheep. (1999) (66)
- Material properties of femoral cancellous bone in axial loading (1980) (62)
- Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth. (2000) (62)
- A non-optimized follower load path may cause considerable intervertebral rotations. (2010) (59)
- Loading of the knee joint during ergometer cycling: telemetric in vivo data. (2012) (58)
- Comparison of loads on internal spinal fixation devices measured in vitro and in vivo. (1997) (58)
- Optimised loads for the simulation of axial rotation in the lumbar spine. (2011) (58)
- A probabilistic finite element analysis of the stresses in the augmented vertebral body after vertebroplasty (2010) (58)
- Comparison of in vivo measured loads in knee, hip and spinal implants during level walking. (2017) (56)
- Mediolateral force distribution at the knee joint shifts across activities and is driven by tibiofemoral alignment (2017) (52)
- Biomechanics: Basic and Applied Research (1987) (50)
- Does aquatic exercise reduce hip and knee joint loading? In vivo load measurements with instrumented implants (2017) (50)
- Braces do not reduce loads on internal spinal fixation devices. (1999) (49)
- Effect of a pedicle-screw-based motion preservation system on lumbar spine biomechanics: a probabilistic finite element study with subsequent sensitivity analysis. (2010) (48)
- A nonlinear finite element analysis of interface conditions in porous coated hip endoprostheses. (1988) (47)
- The effect of laterally wedged shoes on the loading of the medial knee compartment‐in vivo measurements with instrumented knee implants (2011) (47)
- Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants (2005) (47)
- Effect of bone graft characteristics on the mechanical behavior of the lumbar spine. (2002) (46)
- Measured loads on a vertebral body replacement during sitting. (2011) (46)
- Determination of typical patterns from strongly varying signals (2012) (46)
- Telemeterized Load Measurement Using Instrumented spinal Internal Fixators in a Patient With Degenerative Instability (1995) (45)
- In Vivo Hip Joint Loading during Post-Operative Physiotherapeutic Exercises (2013) (45)
- Internal spinal fixator stiffness has only a minor influence on stresses in the adjacent discs. (1999) (44)
- High-Tech Hip Implant for Wireless Temperature Measurements In Vivo (2012) (44)
- Patient monitoring system for load measurement with spinal fixation devices. (1996) (44)
- Effects of stem design and material properties on stresses in hip endoprostheses. (1987) (43)
- In vivo loads on a vertebral body replacement during different lifting techniques. (2016) (41)
- Effects of fusion-bone stiffness on the mechanical behavior of the lumbar spine after vertebral body replacement. (2006) (41)
- In vivo hip joint loads during three methods of walking with forearm crutches. (2013) (41)
- The influence of footwear on knee joint loading during walking--in vivo load measurements with instrumented knee implants. (2013) (40)
- Loads on an internal spinal fixation device during physical therapy. (2002) (40)
- Influence of Muscle Forces on Loads in Internal Spinal Fixation Devices (1998) (39)
- Design and calibration of load sensing orthopaedic implants. (2008) (39)
- Effect of an internal fixator and a bone graft on intersegmental spinal motion and intradiscal pressure in the adjacent regions (2001) (38)
- Different Arm Positions and the Shape of the Thoracic Spine Can Explain Contradictory Results in the Literature About Spinal Loads for Sitting and Standing (2010) (37)
- Loads on an internal spinal fixation device during sitting. (2001) (34)
- Influence of load carrying on loads in internal spinal fixators. (2000) (34)
- Comparison of the mechanical behavior of the lumbar spine following mono- and bisegmental stabilization. (2002) (32)
- In vivo measurement of shoulder joint loads during walking with crutches. (2012) (32)
- Spinal loads during position changes. (2012) (31)
- Optimised in vitro applicable loads for the simulation of lateral bending in the lumbar spine. (2012) (30)
- Monitoring the load on a telemeterised vertebral body replacement for a period of up to 65 months (2013) (30)
- Spinal loads as influenced by external loads: a combined in vivo and in silico investigation. (2015) (29)
- Vitamin E stabilised polyethylene for total knee arthroplasty evaluated under highly demanding activities wear simulation. (2017) (28)
- Postoperative Changes in In Vivo Measured Friction in Total Hip Joint Prosthesis during Walking (2015) (27)
- Lifting up and laying down a weight causes high spinal loads. (2013) (25)
- Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spine (2012) (25)
- Diurnal variations in intervertebral disc height affect spine flexibility, intradiscal pressure and contact compressive forces in the facet joints (2010) (24)
- Changes in the loads on an internal spinal fixator after iliac-crest autograft. (2000) (24)
- Loads on a vertebral body replacement during locomotion measured in vivo. (2014) (23)
- Effect of position and height of a mobile core type artificial disc on the biomechanical behaviour of the lumbar spine (2008) (23)
- In vivo measurements of the effect of whole body vibration on spinal loads (2014) (23)
- [Loads acting on orthopaedic implants. Measurements and practical applications]. (2007) (23)
- In vivo implant forces acting on a vertebral body replacement during upper body flexion. (2015) (23)
- Loads on a spinal implant measured in vivo during whole-body vibration (2010) (22)
- In vitro load measurement using an instrumented spinal fixation device. (1996) (22)
- Comparison of Two Methods for In Vivo Estimation of the Glenohumeral Joint Rotation Center (GH-JRC) of the Patients with Shoulder Hemiarthroplasty (2011) (22)
- Flexible non-fusion scoliosis correction systems reduce intervertebral rotation less than rigid implants and allow growth of the spine: a finite element analysis of different features of orthobiom™ (2008) (21)
- In vivo measured joint friction in hip implants during walking after a short rest (2017) (21)
- CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities (2014) (21)
- Measurement of shoulder joint loads during wheelchair propulsion measured in vivo. (2011) (20)
- Placing a bone graft more posteriorly may reduce the risk of pedicle screw breakage: analysis of an unexpected case of pedicle screw breakage. (1998) (19)
- Effect of different surgical strategies on screw forces after correction of scoliosis with a VDS implant (2006) (19)
- Large sizes of vertebral body replacement do not reduce the contact pressure on adjacent vertebral bodies per se. (2009) (18)
- How does the way a weight is carried affect spinal loads? (2014) (18)
- [Musculoskeletal biomechanics of the knee joint. Principles of preoperative planning for osteotomy and joint replacement]. (2007) (17)
- Correlation between back shape and spinal loads. (2013) (17)
- Biomechanics and Pathomechanics of the Shoulder Joint with Reference to Prosthetic Joint Replacement (1987) (17)
- Analysis of Simulated Single Ligament Transection on the Mechanical Behaviour of a Lumbar Functional Spinal Unit / Rechnerische Analyse des Einflusses der Bänder auf das mechanische Verhalten eines Bewegungssegments der Lendenwirbelsäule (2004) (16)
- Evaluation of ischial weight-bearing orthoses, based on in-vivo hip joint force measurements. (1994) (16)
- Loading of the hip and knee joints during whole body vibration training (2018) (15)
- Medial and lateral foot loading and its effect on knee joint loading. (2015) (15)
- Physical Activities That Cause High Friction Moments at the Cup in Hip Implants (2018) (15)
- In vivo hip joint loads and pedal forces during ergometer cycling. (2017) (15)
- [In vivo measurement of hip joint stress. 1. Physical therapy]. (1989) (13)
- ESB Clinical Biomechanics Award 2018: Muscle atrophy‐related increased joint loading after total hip arthroplasty and their postoperative change from 3 to 50 months (2019) (13)
- Mechanical Properties of the Cement/Bone Bond (1976) (13)
- Telemetrisches Übertragungssystem zur In-vivo-Messung der Belastung des Wirbel-Fixateur interne. Telemetry System for In Vivo Measurement of the Loading of an Internal Spinal Fixation Device (1994) (13)
- Tibio-Femoral Contact Force Distribution is Not the Only Factor Governing Pivot Location after Total Knee Arthroplasty (2019) (12)
- In vivo measurement of implant loads in a patient with a fractured vertebral body (2004) (12)
- Effect of an orthosis on the loads acting on a vertebral body replacement. (2013) (12)
- Spinal Loads during Post-Operative Physiotherapeutic Exercises (2014) (11)
- [Finite element analysis, its limitations and the relevance of its results to orthopaedic surgery as shown by simultaneous experimental measurements (author's transl)]. (2008) (10)
- [The biomechanics of kyphosis]. (2001) (10)
- Five month in vivo measurement of hip joint forces (1989) (9)
- [The stresses in femur (author's transl)]. (2008) (9)
- Spannungsanalyse des Ellbogengelenkes vor und nach Radiuskopf-Resektion - Stress Analysis on the Elbow before and after Radial Head Resection (1986) (8)
- [A telemetric transmission system for in vivo measuring of hip joint force with instrument-implanted prostheses]. (1988) (8)
- [Walking with walking aids. III. Control and training of partial weightbearing by means of instrumented crutches (author's transl)]. (1979) (8)
- Clamping stiffness and its influence on load distribution between paired internal spinal fixation devices. (1996) (8)
- Loads on internal spinal fixation devices (1999) (8)
- COMPARING MODEL-PREDICTED GH-JOINT CONTACT FORCES BY IN-VIVO MEASURED FORCES (2008) (7)
- IN VIVO SHOULDER JOINT FORCES AT ISOLATED MOTIONS (2008) (7)
- European Society of Biomechanics S.M. Perren Award 2022: Standardized tibio-femoral implant loads and kinematics. (2022) (6)
- [Telemetric transmission system for in vivo measurement of the stress load of an internal spinal fixator]. (1994) (6)
- Biomechanical Considerations in the Design of a Semi-constrained Total Shoulder Replacement (1982) (6)
- Founding of the Julius Wolff Institut Charité – Universitätsmedizin Berlin: Editorial Comment (2010) (5)
- Evaluation of Biomechanical Models for the Planning of Total Hip Arthroplasty (2013) (5)
- [Effect of implants for replacement of a vertebral body on the mechanical function of the lumbar spine]. (2002) (5)
- [Evaluation of biomechanical models for therapy planning of total hip arthroplasty - direct comparison of computational results with in vivo measurements]. (2014) (5)
- Wirbelsäulenbelastung beim Sitzen auf einem Bürostuhl mit nach hinten kippbarer Rückenlehne / Loads Acting on the Spine when Seated on an Office Chair with a Tilting Back (2002) (5)
- Load directions at hip prostheses measured in vivo (1989) (5)
- [Loading on internal spinal fixation devices]. (1999) (4)
- IN VIVO MEASUREMENTS OF THE FRICTION MOMENT IN TOTAL HIP JOINT PROSTHESES DURING WALKING (2012) (4)
- [Stress analysis of the shoulder blade following shoulder joint replacement]. (1983) (4)
- Musculoskeletal loading database: loading conditions of the proximal femur (2005) (4)
- Influence of radiation conditions on the wear behaviour of Vitamin E treated UHMWPE gliding components for total knee arthroplasty after extended artificial aging and simulated daily patient activities. (2021) (4)
- [Stress on the elbow joint following alloplastic joint replacement]. (1986) (4)
- Loads on an Internal Spinal Fixation Device Measured In Vivo (2003) (4)
- [Mechanical properties of bonding between cancellous bone and polymethylmetacrylate. IV. Tensile fatigue strength (author's transl)]. (1977) (4)
- Averaging of strongly varying signals. (2001) (4)
- [Stresses on the femur following hip joint replacement]. (1983) (3)
- First in vivo measurements of contact forces in the shoulder joint (2006) (3)
- [Walking with canes and forearm-crutches (author's transl)]. (1978) (3)
- [Stress measurements with an instrumented internal spinal fixator]. (1993) (3)
- The Load upon the Artifical Hip Joint During Cycling (1990) (3)
- [Walking with canes and forearm-crutches. I. Reduction of loads at the hip and proximal end of the femur by one sided use of cane/crutch (author's transl)]. (1977) (3)
- Ein nichtlineares Finite-Element-Modell zur Bestimmung der Grenzflächenspannungen bei Hüftendoprothesen - A Non-Linear, Finite Element Model for Interface Stresses in Total Hip Replacements (1988) (3)
- IN VIVO MEASUREMENTS OF LOADS DURING ERGOMETER CYCLING 6 MONTHS POST-OPERATIVELY (2008) (2)
- [The stresses in femur. I. Intact femur without consideration of the iliotibial tract (author's transl)]. (1980) (2)
- [Biomechanical consequences of variations in artificial disc positioning. A finite element study on the lumbar spine]. (2007) (2)
- Of men and sheep — Comparison of their hip joint forces (1982) (2)
- Averaging of Strongly Varying Signals - Mittelung stark variierender Signale (2001) (2)
- [Analysis of the tension of the elbow joint before and after resection of the radius head]. (1986) (2)
- Spinal Loads during Cycling on an Ergometer (2014) (2)
- How well does a musculoskeletal model predict GH-joint contact forces? Comparison with in-vivo data (2009) (2)
- [Effect of a double intervertebral cage on the mechanical behavior of the lumbar spine]. (2002) (2)
- The effect of implant material on friction induced heating around total hip implants (2000) (2)
- Long term animal test with instrumented hip implants (1987) (2)
- KNEE ADDUCTION MOMENT AND MEDIAL CONTACT FORCE – FACTS ABOUT THE CORRELATION DURING GAIT (2012) (2)
- Frictional heating in and around total hip implants (2000) (2)
- LOADING OF THE GLENOHUMERAL JOINT DURING EVERYDAY LIFE (2008) (1)
- Biomechanics of the hip joint (2003) (1)
- Relative contribution of different muscle energy consumption processes in an energy-based muscle load sharing cost function (2013) (1)
- [The stress on the femur, cement and implant following implantation of a hip prosthesis]. (1982) (1)
- Changes in the loads on an internal spinal fixator after iliac-crest autograft (2000) (1)
- Insight from direct in vivo measurements on the force distribution across the human knee in flexion: can it be modified, and can the internal loads be predicted from external measurements? (2014) (1)
- Mechanical Loading 2 (2001) (1)
- Methods for Avoiding or Reducing High Spinal Loads in Everyday Life (2014) (1)
- Instrumented orthopaedic implantsa—An overview (2006) (1)
- [In-vitro measurement of loading using an instrumented vertebral internal fixator]. (1995) (1)
- Accuracy considerations for an instrumented tibial baseplate (2006) (1)
- [Stiffening effect of a transsacral fusion system for the lumbosacral junction. A probabilistic finite element analysis and sensitivity study]. (2011) (1)
- [Effect of clamping tensile strength on load distribution in paired mounted spinal internal fixators]. (1994) (1)
- Re: The Effect of Running Shoes on Lower Extremity Joint Torques (2010) (1)
- Wear of Knee Implants: Are the ISO Test Loads Realistic? (2013) (1)
- [Spinal load bearing during sitting in an office chair with a tilting back]. (2002) (1)
- METHOD TO EVALUATE THE DELAMINATION RISK OF TKA POLYETHYLENE MATERIALS (2017) (1)
- HIP IMPLANT FOR TEMPERATURE MEASUREMENTS (2012) (1)
- In vitro measurements of loads and moments using an instrumented tibial tray (2006) (1)
- Loads on an internal spinal fixation device in the postoperative temporal course (1998) (1)
- Die Beanspruchung des Ellbogengelenkes nach alloplastischem Gelenkersatz - Stresses on the Elbow after Joint Replacement (1986) (1)
- Smart implants with inductive power supply and radio-frequency data link (2006) (0)
- ESB Research Award Frictional heating of total hip implants. Part 2: finite element study (2001) (0)
- Optimal or antagonistic? muscle force solutions in the lower limb (2005) (0)
- [Microradiography and macroradiography with an industrial X-ray inspection-apparatus (author's transl)]. (1975) (0)
- In Vivo Tibiofemoral Joint Contact Forces During High Flexion Activities (2012) (0)
- DEFORMATION OF THE LUMBAR SPINE DURING STANDING STRONGLY DEPENDS ON ASSUMED LOADING CONDITIONS (2008) (0)
- [Non-linear finite-element model for the determination of interface stresses in total hip prostheses]. (1988) (0)
- [An experimental model for Wolff's law]. (1978) (0)
- Stochastic analysis of multilevel artificial disc replacement and impact on spinal balance (2011) (0)
- FINITE-ELEMENT-ANALYSIS OF AN INSTRUMENTED TIBIAL BASEPLATE (2008) (0)
- Influence of Cement Augmentation on Intradiscal Pressure: A Finite Element Study (2005) (0)
- PEAK KNEE ADDUCTION MOMENTS & MEDIAL CONTACT FORCES – RELATIONS ACROSS SUBJECTS AND ACTIVITIES (2012) (0)
- [Critical comment on the work of G. Ritter et al.: "Elastic strapping of hip joint prosthesis". (Arch. orthop. Unfall-Chir. 86, 1-14 (1976))]. (1977) (0)
- Biomechanics: Basic and Applied Research: "Selected Proceedings of the Fifth Meeting of the European Society of Biomechanics, September 8-10, 1986, Berlin, F.R.G." (2011) (0)
- Author Correction: Tibio-Femoral Contact Force Distribution is Not the Only Factor Governing Pivot Location after Total Knee Arthroplasty (2019) (0)
- Sensitivity analysis of biomechanical models for total hip arthroplasty (2014) (0)
- HOLDING A WEIGHT WITH ELEVATED ARMS STRONGLY INCREASES THE LOADS ON A SPINAL IMPLANT (2008) (0)
- Two-dimensional mechanical model of the upper end of the humerus. (2001) (0)
- [Critical observations and the loads on femoral head replacement and the femoral bone calculated for a support in 3 points (author's transl)]. (1977) (0)
- P030 Estimation of lumbar spine muscle forces using the finite element method and loads measured in spinal fixation devices (1998) (0)
- An instrumented spinal skeletal fixation device for load measurements (1991) (0)
- Determination of the glenohumeral joint reaction force at archery (2011) (0)
- Influence of stem length and collar presence on stresses in hip prosthesis (1982) (0)
- An instrumented vertebral body replacement for in vivo load measurements (2006) (0)
- [Shoulder joint replacement-using the Kölbel-Friedebold method]. (1977) (0)
- AN ORTHOSIS HAS ONLY A MINOR EFFECT ON THE LOADS ACTING ON A SPINAL IMPLANT (2012) (0)
- Spannungsanalyse am Schulterblatt nach Schultergelenkersatz. Stress Analysis at the Scapula after Shoulder Joint Replacement (1983) (0)
- PROBABILISTIC FINITE ELEMENT ANALYSIS OF THE LUMBAR SPINE AFTER TOTAL DISC ARTHROPLASTY (2008) (0)
- P034 Influence of lumbar spine curvature on stress distribution in intervertebral discs (1998) (0)
- Hip joint forces, calculated and measured: an evaluation of musculo-skeletal modelling (2002) (0)
- LOADS DURING SIMULATOR AND CADAVER TESTING MEASURED WITH AN INSTRUMENTED TKA (2007) (0)
- AN INSTRUMENTED SHOULDER ENDOPROSTHESIS FOR MEASURING JOINT LOADS IN VIVO (2008) (0)
- Author Correction: Tibio-Femoral Contact Force Distribution is Not the Only Factor Governing Pivot Location after Total Knee Arthroplasty (2019) (0)
- Tibio-Femoral Contact Force Distribution is Not the Only Factor Governing Pivot Location after Total Knee Arthroplasty (2019) (0)
- [Patho-mechanics of the shoulder]. (1981) (0)
- Evaluation of 2D Biomechanical Models of the Knee of One-Leg Stand for Total Knee Arthroplasty Planning (2017) (0)
- [Mechanical response of femur spongiosa tissue in axial compression]. (1979) (0)
- Artificial disc position influences forces and intersegmental rotations in the lumbar spine (2006) (0)
- Effect of a posterior dynamic implant on the mechanical behavior of the lumbar spine (2006) (0)
- [The stress on the anchoring zone in artificial hip joints. Mathematical and experimental analysis (proceedings)]. (1978) (0)
- CLINICALLY USED ARTIFICIAL DISCS HAVE A SIMILAR EFFECT ON LUMBAR SPINE MECHANICS (2008) (0)
- [A technique for reproducible roentgenograms of the intercondylar sulcus for the study of the femoropatellar (author's transl)]. (1979) (0)
- EuroSpine 2006. 8th Annual Meeting of the European Spine Society, 25–28 October 2006, Istanbul, Turkey - Abstracts (2006) (0)
- VITAMIN E STABILISED POLYETHYLENE MATERIALS FOR TKA EVALUATED UNDER HIGHLY DEMANDING PATIENT DAILY ACTIVITIES IN VITRO (2016) (0)
- NORMATIVE DATA OF TKR LOADING FOR LEVEL WALKING AND STAIR CLIMBING MEASURED IN VIVO (2008) (0)
- Direct measurement of hip joint forces in sheep (1980) (0)
- Low power 9-channel telemetry transmitter on a single chip (2006) (0)
- Calibration and design improvement of load sensing orthopaedic implants (2006) (0)
- Finite Element Analysis of the Elbow After Joint Replacement (1989) (0)
- Influence of a screw with a hinge on the pull-out force at the cranial end vertebra in ventral derotation spondylodesis (VDS) (2003) (0)
- Three dimensional finite element analysis and experimental investigation of strain in the femur with and without prosthetic replacement (1980) (0)
- Musculoskeletal loading and its implication for clinical practice (2001) (0)
This paper list is powered by the following services:
What Schools Are Affiliated With Georg Bergmann?
Georg Bergmann is affiliated with the following schools:
