W. H. William H. Harris
#54,896
Most Influential Person Now
W. H. William H. Harris's AcademicInfluence.com Rankings
W. H. William H. Harrisphilosophy Degrees
Philosophy
#1748
World Rank
#3117
Historical Rank
Logic
#302
World Rank
#611
Historical Rank
Download Badge
Philosophy
W. H. William H. Harris's Degrees
- Doctorate Medicine Johns Hopkins University
Why Is W. H. William H. Harris Influential?
(Suggest an Edit or Addition)W. H. William H. Harris's Published Works
Published Works
- Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. (1969) (6281)
- Collaborative overview of randomised trials of antiplatelet therapy Prevention of death, myocardial infarction, and stroke by prolonged antiplatelet therapy in various categories of patients (1994) (3667)
- The Etiology of Osteoarthritis of the Hip (1986) (1155)
- Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. (1992) (950)
- The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. (1983) (872)
- Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. (1990) (783)
- Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. (1992) (758)
- Rates and Outcomes of Primary and Revision Total Hip Replacement in the United States Medicare Population (2003) (733)
- Femoral component loosening using contemporary techniques of femoral cement fixation. (1982) (717)
- Association Between Hospital and Surgeon Procedure Volume and Outcomes of Total Hip Replacement in the United States Medicare Population* (2001) (666)
- Total Hip and Total Knee Replacement (1990) (622)
- Contact pressures in the human hip joint measured in vivo. (1986) (599)
- A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. (2001) (594)
- The problem is osteolysis. (1995) (558)
- The initiation of failure in cemented femoral components of hip arthroplasties. (1991) (548)
- Incidence Rates of Dislocation, Pulmonary Embolism, and Deep Infection During the First Six Months After Elective Total Hip Replacement (2003) (488)
- The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review. (1990) (486)
- Wear and periprosthetic osteolysis: the problem. (2001) (439)
- Extensive localized bone resorption in the femur following total hip replacement. (1976) (438)
- Loosening of the femoral component after use of the medullary-plug cementing technique. Follow-up note with a minimum five-year follow-up. (1986) (425)
- Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). (1999) (425)
- Production of cytokines around loosened cemented acetabular components. Analysis with immunohistochemical techniques and in situ hybridization. (1993) (420)
- The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. (1992) (409)
- In Vivo Skeletal Responses to Porous-Surfaced Implants Subjected to Small Induced Motions* (1997) (407)
- Proximal placement of the acetabular component in total hip arthroplasty. A long-term follow-up study. (1991) (384)
- The natural history of fibrous dysplasia. An orthopaedic, pathological, and roentgenographic study. (1962) (383)
- SYMPOSIUM: PAPERS PRESENTED AT THE ANNUAL CLOSED MEETING OF THE INTERNATIONAL HIP SOCIETY The Etiology of Osteoarthritis of the Hip An Integrated Mechanical Concept (2007) (378)
- Endosteal erosion in association with stable uncemented femoral components. (1990) (374)
- Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem. Ultra High Molecular Weight Poly Ethylene. (1996) (365)
- Localized osteolysis in stable, non-septic total hip replacement. (1986) (353)
- Contact pressures from an instrumented hip endoprosthesis. (1989) (346)
- A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. (1992) (342)
- Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes. (2005) (342)
- Total hip replacement and femoral-head bone-grafting for severe acetabular deficiency in adults. (1977) (327)
- Limitations of the continuum assumption in cancellous bone. (1988) (322)
- Osteolysis and particle disease in hip replacement. A review. (1994) (322)
- Failure of acetabular autogenous grafts in total hip arthroplasty. Increasing incidence: a follow-up note. (1990) (321)
- Quantification of Implant Micromotion, Strain Shielding, and Bone Resorption With Porous‐Coated Anatomic Medullary Locking Femoral Prostheses (1992) (318)
- Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components. (1978) (317)
- Bulk Structural Autogenous Grafts and Allografts for Reconstruction of the Acetabulum in Total Hip Arthroplasty. Sixteen-Year-Average Follow-up* (1997) (308)
- Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. (2004) (291)
- Bone lysis in well-fixed cemented femoral components. (1990) (270)
- Aspirin Prophylaxis of Venous Thromboembolism after Total Hip Replacement (1977) (267)
- Formation of a synovial-like membrane at the bone-cement interface. Its role in bone resorption and implant loosening after total hip replacement. (1986) (255)
- Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study. (1995) (253)
- Histomorphological studies of the long-term skeletal responses to well fixed cemented femoral components. (1990) (249)
- The value of aspiration of the hip joint before revision total hip arthroplasty. (1993) (236)
- Skeletal renewal and metabolic bone disease. (1969) (235)
- Comparison of warfarin, low-molecular-weight dextran, aspirin, and subcutaneous heparin in prevention of venous thromboembolism following total hip replacement. (1974) (231)
- The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years. (1992) (227)
- The Harris hip score: comparison of patient self-report with surgeon assessment. (2001) (227)
- Micromotion of cemented and uncemented femoral components. (1991) (224)
- Femoral head autografting to augment acetabular deficiency in patients requiring total hip replacement. A minimum five-year and an average seven-year follow-up study. (1986) (221)
- Etiology of osteoarthritis of the hip. (1986) (218)
- Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. (2001) (217)
- Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. (1996) (215)
- Association of hospital and surgeon volume of total hip replacement with functional status and satisfaction three years following surgery. (2003) (210)
- In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. (2005) (205)
- Total hip and total knee replacement : second of two parts (1990) (204)
- High failure rate of bulk femoral head allografts in total hip acetabular reconstructions at 10 years. (1993) (198)
- Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allografts. (1990) (194)
- The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement. (1992) (192)
- Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement. (1999) (190)
- Biomechanical and histologic investigation of cemented total hip arthroplasties. A study of autopsy-retrieved femurs after in vivo cycling. (1989) (187)
- Revision Total Hip Arthroplasty with Use of So-Called Second-Generation Cementing Techniques for Aseptic Loosening of the Femoral Component. A Fifteen-Year-Average Follow-up Study* (1996) (187)
- The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. A retrospective matched-pair series. (1994) (186)
- The three-dimensional anatomy of haversian systems. (1958) (179)
- The Harris-Galante porous-coated acetabular component with screw fixation. An average ten-year follow-up study. (1999) (175)
- Reduction in venous thromboembolism by agents affecting platelet function. (1971) (175)
- Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations* (1997) (174)
- Failed total hip replacement: assessment by plain radiographs, arthrograms, and aspiration of the hip joint. (1984) (167)
- Revision of the acetabular component with an uncemented Harris-Galante porous-coated prosthesis. (1992) (165)
- Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug. (1978) (156)
- Total hip arthroplasty in the treatment of adult hips with current or quiescent sepsis. (1981) (155)
- Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement. (1984) (154)
- Characterization of irradiated blends of alpha-tocopherol and UHMWPE. (2005) (154)
- High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years. (1999) (150)
- Stress distributions in the acetabular region--I. Before and after total joint replacement. (1982) (147)
- Effects on intact femora of dogs of the application and removal of metal plates. A metabolic and structural study comparing stiffer and more flexible plates. (1978) (145)
- Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses. (1994) (143)
- Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts. (2004) (142)
- Prevention of venous thromboembolism in orthopaedic patients. (1976) (141)
- A Microscopic Method of determining Rates of Bone Growth (1960) (140)
- Stress distributions in the acetabular region--II. Effects of cement thickness and metal backing of the total hip acetabular component. (1982) (138)
- A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components. (1991) (137)
- Hybrid total hip replacement. A 6.5-year follow-up study. (1993) (136)
- A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life. (1992) (133)
- Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. (2000) (132)
- Low-dose warfarin versus external pneumatic compression for prophylaxis against venous thromboembolism following total hip replacement. (1987) (131)
- Deep-wound infection after total hip replacement under contemporary aseptic conditions. (1988) (130)
- The Otto Aufranc Award. Skeletal response to well fixed femoral components inserted with and without cement. (1996) (128)
- Bony ingrowth fixation of the acetabular component in canine hip joint arthroplasty. (1983) (127)
- Complex total hip replacement for dysplastic or hypoplastic hips using miniature or microminiature components. (1983) (127)
- The in vivo distribution of tetracyclines in canine bone. (1962) (127)
- Complications related to modularity of total hip components. (1993) (127)
- The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. (1994) (126)
- Large Diameter Femoral Heads on Highly Cross-linked Polyethylene: Minimum 3-year Results (2006) (126)
- High placement of porous-coated acetabular components in complex total hip arthroplasty. (1994) (125)
- Management of limb length inequality during total hip replacement. (1996) (123)
- A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component. (1994) (122)
- Intra-articular acetabular labrum: a possible etiological factor in certain cases of osteoarthritis of the hip. (1979) (120)
- Further follow-up on socket fixation using a metal-backed acetabular component for total hip replacement. A minimum ten-year follow-up study. (1987) (120)
- Third-body wear of highly cross-linked polyethylene in a hip simulator. (2003) (119)
- Molecular rearrangements in ultra high molecular weight polyethylene after irradiation and long-term storage in air (1999) (119)
- Differential effects of different forms of hydroxyapatite and hydroxyapatite/tricalcium phosphate particulates on human monocyte/macrophages in vitro. (1996) (118)
- In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals. (2006) (117)
- A finite element study of the initiation of failure of fixation in cemented femoral total hip components (1992) (115)
- Is It Advantageous to Strengthen the Cement‐Metal Interface and Use a Collar for Cemented Femoral Components of Total Hip Replacements? (1992) (113)
- Femoral component offset. Its effect on strain in bone-cement. (1993) (113)
- Prophylaxis of deep-vein thrombosis after total hip replacement. Dextran and external pneumatic compression compared with 1.2 or 0.3 gram of aspirin daily. (1985) (112)
- Differences in stiffness of the interface between a cementless porous implant and cancellous bone in vivo in dogs due to varying amounts of implant motion. (1996) (110)
- Revision of nonseptic, loose, cemented femoral components using modern cementing techniques. (1988) (108)
- Comparison of 125I fibrinogen count scanning with phlebography for detection of venous thrombi after elective hip surgery. (1975) (106)
- Total hip arthroplasty with insertion of the acetabular component without cement in hips with total congenital dislocation or marked congenital dysplasia. (1999) (105)
- Advances in surgical technique for total hip replacement: without and with osteotomy of the greater trochanter. (1980) (105)
- Total hip and total knee replacement (1). (1990) (105)
- Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study. (1999) (103)
- Etiology of Osteolysis Around Porous‐Coated Cementless Total Hip Arthroplasties (1994) (101)
- OBSERVATIONS ON THE ROOT ANATOMY OF RICE (ORYZA SATIVA L.) (1981) (100)
- Total hip replacement for developmental dysplasia of the hip. (1995) (100)
- Influence of antibiotic impregnation on the fatigue life of Simplex P and Palacos R acrylic bone cements, with and without centrifugation. (1989) (99)
- Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. (2007) (98)
- Long-term results of cemented femoral revision surgery using second-generation techniques. An average 11.7-year follow-up evaluation. (1994) (98)
- Comparison of the fatigue characteristics of centrifuged and uncentrifuged simplex P bone cement (1987) (97)
- Surface analysis of early retrieved acetabular polyethylene liners: a comparison of conventional and highly crosslinked polyethylenes. (2004) (97)
- Minimum 6-year Followup of Highly Cross-linked Polyethylene in THA (2007) (97)
- Ingrowth of bone in failed fixation of porous-coated femoral components. (1991) (97)
- Results of cementless revisions of total hip arthroplasties using the Harris-Galante prosthesis. (1988) (95)
- Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum--I. Ultrasonic measurement of acetabular surfaces, sphericity and cartilage thickness. (1981) (95)
- Factors influencing stability at the interface between a porous surface and cancellous bone: a finite element analysis of a canine in vivo micromotion experiment. (1997) (94)
- Comparison of a hybrid with an uncemented total hip replacement. A retrospective matched-pair study. (1990) (91)
- The histology of the radiolucent line. (1992) (91)
- Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum. II Instrumented endoprosthesis measurement of articular surface pressure distribution. (1981) (90)
- Total hip and total knee replacement (2) (1990) (89)
- Thigh pain despite bone ingrowth into uncemented femoral stems. (1992) (89)
- Biologic fixation of total hip implants. Insights gained from a series of canine studies. (2004) (88)
- Hybrid total hip arthroplasty. (1989) (86)
- Surveillance of deep vein thrombosis in asymptomatic total hip replacement patients. Impedance phlebography and fibrinogen scanning versus roentgenographic phlebography. (1988) (86)
- Surface damage to cobalt-chrome femoral head prostheses. (1994) (86)
- Incidence of heterotopic ossification after total hip replacement: effect of the type of fixation of the femoral component. (1991) (85)
- Socket fixation using a metal-backed acetabular component for total hip replacement. A minimum five-year follow-up. (1982) (84)
- A method of intraoperative limb length measurement in total hip arthroplasty. (1985) (84)
- Importance of a Thin Cement Mantle: Autopsy Studies of Eight Hips (1998) (84)
- Aspirin prophylaxis of venous thromboembolism after total hip replacement. (1978) (84)
- Autopsy studies of the bone-cement interface in well-fixed cemented total hip arthroplasties. (1993) (83)
- Histology of porous-coated acetabular components. 25 cementless cups retrieved after arthroplasty. (1993) (81)
- Total Hip Arthroplasty with Use of Second-Generation Cementing Techniques. An Eighteen-Year-Average Follow-up Study* (1998) (80)
- Anticoagulation for prevention of thromboembolism following fractures of the hip. (1966) (80)
- Analysis of Long-Term Cemented Total Hip Arthroplasty Retrievals (2002) (80)
- The Harris-Galante uncemented femoral component in primary total hip replacement at 10 years. (1999) (79)
- A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty. (2001) (78)
- Range of motion in contemporary total hip arthroplasty. The impact of modular head-neck components. (1991) (78)
- Postoperative Mortality after Total Hip Arthroplasty. An Analysis of Deaths after Two Thousand Seven Hundred and Thirty-six Procedures* (1998) (78)
- Optical analysis of surface changes on early retrievals of highly cross-linked and conventional polyethylene tibial inserts. (2003) (77)
- Comparison of the mechanical properties of Simplex P, Zimmer Regular, and LVC bone cements. (1987) (77)
- Allografting in total hip arthroplasty: in adults with severe acetabular deficiency including a surgical technique for bolting the graft to the ilium. (1982) (75)
- Gradient crosslinking of UHMWPE using irradiation in molten state for total joint arthroplasty. (2002) (75)
- The prevention of thromboembolic disease by prophylactic anticoagulation. A controlled study in elective hip surgery. (1967) (75)
- Routine use of adjusted low-dose warfarin to prevent venous thromboembolism after total hip replacement. (1993) (74)
- Cementless acetabular revision with the Harris-Galante porous prosthesis. Results after a minimum of ten years of follow-up. (2004) (74)
- Massive allografting for severe failed total hip replacement. (1986) (74)
- Cost-effectiveness of prophylaxis in total hip replacement. (1991) (74)
- Polyethylene damage in total knees and use of highly crosslinked polyethylene. (2003) (72)
- Factors affecting cement strains near the tip of a cemented femoral component. (1997) (72)
- 20-year experience with cemented primary and conversion total hip arthroplasty using so-called second-generation cementing techniques in patients aged 50 years or younger. (2000) (72)
- Total hip reconstruction using frozen femoral head allografts in patients with acetabular bone loss. (1987) (72)
- Femoral head sizes larger than 32 mm against highly cross-linked polyethylene. (2002) (72)
- Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads. (1991) (71)
- Extensive porosity at the cement-femoral prosthesis interface: a preliminary study. (1993) (70)
- The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners. (2006) (70)
- Conquest of a worldwide human disease: particle-induced periprosthetic osteolysis. (2004) (70)
- Loci of movement of selected points on the femoral head during normal gait. Three-dimensional computer simulation. (1996) (70)
- High and low-dose aspirin prophylaxis against venous thromboembolic disease in total hip replacement. (1982) (70)
- Acrylic Fragmentation in Total Hip Replacements and Its Biological Consequences (1992) (69)
- Aggressive Wear Testing of a Cross-Linked Polyethylene in Total Knee Arthroplasty (2002) (69)
- A radio telemetry device for monitoring cartilage surface pressures in the human hip. (1974) (69)
- Effect of Radiation, Heat, and Aging on In Vitro Wear Resistance of Polyethylene (2003) (69)
- Histologic identification of polyethylene wear debris using Oil Red O stain. (1993) (68)
- Trochanteric osteotomy for revision total hip arthroplasty. 97% union rate using a comprehensive approach. (1988) (68)
- Increasing prevalence of femoral lysis in cementless total hip arthroplasty. (1995) (68)
- A review of current cross-linked polyethylenes used in total joint arthroplasty. (2005) (67)
- Determination of loading parameters in the canine hip in vivo. (1993) (66)
- Survey of prophylaxis against venous thromboembolism in adults undergoing hip surgery. (1987) (66)
- The effect of centrifuging bone cement. (1989) (65)
- The use of wire mesh in total hip replacement surgery. (1975) (63)
- The Efficacy of BMP-2 to Induce Bone Ingrowth in a Total Hip Replacement Model (2003) (63)
- Knee Simulator Wear of Polyethylene Tibias Articulating against Explanted Rough Femoral Components (2004) (63)
- Reattachment of the greater trochanter in total hip-replacement arthroplasty. A new technique. (1978) (63)
- A study of intrusion characteristics of low viscosity cement Simplex-P and Palacos cements in a bovine cancellous bone model. (1987) (62)
- Comparison of bone ingrowth into cobalt chrome sphere and titanium fiber mesh porous coated cementless canine acetabular components. (1993) (62)
- Treatment of unreduced traumatic posterior dislocations of the hip. (1979) (62)
- Osteolysis around uncemented acetabular components of cobalt-chrome surface replacement hip arthroplasty. (1994) (62)
- Alternative materials to improve total hip replacement tribology. (2003) (62)
- Spatial and Temporal Variations in Cortical Bone Formation in Dogs: A LONG-TERM STUDY (1968) (60)
- Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up. (2006) (60)
- Primary cementless acetabular components in hips with severe developmental dysplasia or total dislocation. A concise follow-up, at an average of sixteen years, of a previous report. (2006) (59)
- Will stress shielding limit the longevity of cemented femoral components of total hip replacement? (1992) (59)
- High placement of noncemented acetabular components in revision total hip arthroplasty. A concise follow-up, at a minimum of fifteen years, of a previous report. (2006) (58)
- Acetabular and Femoral Fixation 15 Years After Cemented Total Hip Surgery (1997) (58)
- Results of implant retrieval from postmortem specimens in patients with well-functioning, long-term total hip replacement. (1992) (58)
- Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert. (2007) (58)
- Influence of cartilage geometry on the pressure distribution in the human hip joint. (1979) (58)
- Challenge to the concept that UHMWPE acetabular components oxidize in vivo. (1993) (57)
- The measurement of creep in ultrahigh molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene. (2005) (57)
- Cuff-impedance phlebography and 125I fibrinogen scanning versus roentgenographic phlebography for diagnosis of thrombophlebitis following hip surgery. A preliminary report. (1976) (56)
- The femoral cement compactor. An improvement in cementing technique in total hip replacement. (1983) (56)
- The First 50 Years of Total Hip Arthroplasty: Lessons Learned (2009) (56)
- Cemented total hip arthroplasty following previous femoral osteotomy: an average 16-year follow-up study. (1998) (56)
- Strain-controlled fatigue of acrylic bone cement. (1982) (56)
- Prevention of venous thromboembolism following total hip replacement. Warfarin vs dextran 40. (1972) (55)
- Metrology to Quantify Wear and Creep of Polyethylene Tibial Knee Inserts (2003) (54)
- Can the western Ontario and McMaster Universities (WOMAC) osteoarthritis index be used to evaluate different hip joints in the same patient? (1996) (54)
- Fit of the uncemented femoral component and the use of cement influence the strain transfer to the femoral cortex (1994) (54)
- Effect of hand mixing tobramycin on the fatigue strength of Simplex P. (1991) (54)
- Bone ingrowth into porous coated canine acetabular replacements: the effect of pore size, apposition, and dislocation. (1985) (53)
- Arthroplasty implant registries over the past five decades: Development, current, and future impact (2018) (53)
- Trochanteric Osteotomy for Total Hip Arthroplasty: Six Variations and Indications for Their Use (1996) (52)
- Correlation of measured range of hip motion following total hip arthroplasty and responses to a questionnaire. (1996) (52)
- Porosity of various preparations of acrylic bone cements. (1990) (52)
- The high hip center. (2004) (52)
- Intraoperative measurement of rotational stability of femoral components of total hip arthroplasty. (1991) (52)
- Comparison of Femoral Head Penetration Using RSA and the Martell Method (2006) (52)
- A new lateral approach to the hip joint. (1967) (51)
- Elevated-rim acetabular components. Effect on range of motion and stability in total hip arthroplasty. (1991) (50)
- Skeletal renewal and metabolic bone disease. (1969) (50)
- Topical hemostatic agents to reduce bleeding from cancellous bone. A comparison of microcrystalline collagen, thrombin, and thrombin-soaked gelatin foam. (1976) (50)
- Revision surgery for failed, nonseptic total hip arthroplasty: the femoral side. (1982) (49)
- A new total hip implant. (1971) (48)
- The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components. (1993) (48)
- Detection of pulmonary emboli after total hip replacement using serial C15O2 pulmonary scans. (1984) (48)
- Ex Vivo Wear of Conventional and Cross-linked Polyethylene Acetabular Liners (2005) (47)
- Revision of the Femoral Component of a Total Hip Arthroplasty with the Calcar-Replacement Femoral Component. Results after a Mean of 10.8 Years Postoperatively* (1996) (47)
- The role of acetabular component screw holes and/or screws in the development of pelvic osteolysis (1999) (47)
- Edge Loading Has a Paradoxical Effect on Wear in Metal-on-Polyethylene Total Hip Arthroplasties (2012) (47)
- A system for trochanteric osteotomy and reattachment for total hip arthroplasty with a ninety-nine percent union rate. (1986) (47)
- Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement. (1997) (46)
- Enhancement of the value of hip questionnaires by telephone follow-up evaluation. (1997) (46)
- Matched-pair analysis of cemented and cementless acetabular reconstruction in primary total hip arthroplasty. (2001) (46)
- Third-body wear testing of a highly cross-linked acetabular liner: the effect of large femoral head size in the presence of particulate poly(methyl-methacrylate) debris. (2005) (46)
- In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair‐climbing (1996) (46)
- Enhanced stability of uncemented canine femoral components by bone ingrowth into the porous coatings. (1997) (46)
- Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties (1998) (45)
- Effect of consolidation on adhesive and abrasive wear of ultra high molecular weight polyethylene. (2003) (45)
- The first 32 years of total hip arthroplasty. One surgeon's perspective. (1992) (45)
- Standing versus Supine Radiographs in RSA Evaluation of Femoral Head Penetration (2006) (44)
- Identification and quantification of irradiation in UHMWPE through trans-vinylene yield. (2001) (43)
- Modern use of modern cement for total hip replacement. (1988) (43)
- Long Term Results of Cemented Femoral Stems With Roughened Precoated Surfaces (1998) (43)
- Trochanteric union following revision total hip arthroplasty. (1998) (42)
- Topical hemostatic agents for bone bleeding in humans. A quantitative comparison of gelatin paste, gelatin sponge plus bovine thrombin, and microfibrillar collagen. (1978) (41)
- Hybrid total hip replacement: rationale and intermediate clinical results. (1996) (41)
- Tensile bonding strength of the cement-prosthesis interface. (1994) (40)
- The influence of support conditions in the loading fixture on failure mechanisms in the push‐out test: A finite element study (1990) (40)
- Periacetabular stress distributions after joint replacement with subchondral bone retention. (1983) (40)
- Comparison of hip simulator wear of 2 different highly cross-linked ultra high molecular weight polyethylene acetabular components using both 32- and 38-mm femoral heads. (2007) (40)
- In vitro and in vivo studies of pressurization of femoral cement in total hip arthroplasty. (1993) (40)
- Acetabular Revision After Failed Total Hip Arthroplasty in Patients with Congenital Hip Dislocation and Dysplasia: Results After a Mean of 8.6 Years* (2000) (40)
- Results of Uncemented Cups: A Critical Appraisal at 15 Years (2003) (40)
- Bone ingrowth into porous coated canine total hip replacements. Quantification by backscattered scanning electron microscopy and image analysis. (1989) (39)
- Changes in long‐bone structural properties during the first 8 weeks of plate implantation (1984) (39)
- A new approach to total hip replacement without osteotomy of the greater trochanter. (1975) (39)
- Optimization and comparison of three vacuum mixing systems for porosity reduction of Simplex P cement. (1990) (38)
- A clinical evaluation of aspirin prophylaxis of thromboembolic disease after total hip arthroplasty. (1976) (38)
- Femoral cement pressurization during total hip arthroplasty. The role of different femoral stems with reference to stem size and shape. (1984) (38)
- In vitro comparison of frictional torque and torsional resistance of aged conventional gamma-in-nitrogen sterilized polyethylene versus aged highly crosslinked polyethylene articulating against head sizes larger than 32 mm (2006) (38)
- Reconstruction at a high hip center in acetabular revision surgery using a cementless acetabular component. (1998) (38)
- Advances in total hip arthroplasty. The metal-backed acetabular component. (1984) (38)
- Results of total hip reconstruction using acetabular mesh in patients with central acetabular deficiency. (1988) (37)
- Monitoring the integrity of the cement-metal interface of total joint components in vitro using acoustic emission and ultrasound. (1996) (37)
- Design concepts, indications, and surgical technique for use of the protrusio shell. (1982) (37)
- Isolated acetabular revision with use of the Harris-Galante Cementless Component. Study with intermediate-term follow-up. (2004) (37)
- Management of the deficient acetabulum using cementless fixation without bone grafting. (1993) (37)
- Total Hip Arthroplasty Performed with Insertion of the Femoral Component with Cement and the Acetabular Component without Cement. Ten to Thirteen-Year Results* (1997) (36)
- Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros. (2004) (36)
- A novel constrained acetabular liner design with increased range of motion. (2001) (35)
- The next critical role of orthopedic registries (2015) (34)
- THE IN VIVO INHIBITION OF BONE FORMATION BY ALIZARIN RED S. (1964) (34)
- Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous-coated femoral components. (1995) (34)
- Revision of failed acetabular components with use of so-called jumbo noncemented components. A concise follow-up of a previous report. (2006) (33)
- Clinical evaluation and cost effectiveness of preoperative laboratory assessment on patients undergoing total hip arthroplasty. (1989) (33)
- The plated femur: relationships between the changes in bone stresses and bone loss. (1981) (33)
- Early and late loosening of the acetabular cup after low friction arthroplasty. (1993) (33)
- Clinical results using the Mueller-Charnley total hip prosthesis. (1972) (33)
- A cement fixation system for total hip arthroplasty. (1982) (33)
- Prophylaxis for heterotopic bone formation after total hip arthroplasty using low-dose radiation in high-risk patients. (1992) (32)
- Effect of lipid absorption on wear and compressive properties of unirradiated and highly crosslinked UHMWPE: an in vitro experimental model. (2004) (31)
- Induced hypotensive anesthesia for total hip replacement. (1974) (31)
- Tensile fatigue failure of acrylic bone cement. (1983) (31)
- The effect of centrifugation on the fatigue life of bone cement in the presence of surface irregularities. (1988) (31)
- Preliminary report of results of Harris total hip replacement. (1973) (30)
- High assembly strains and femoral fractures produced during insertion of uncemented femoral components. A cadaver study. (1993) (30)
- Light microscopic identification of submicron polyethylene wear debris (1993) (30)
- Wear of retrieved cemented polyethylene acetabula with alumina femoral heads. (1997) (29)
- The Inhibition of Ossification In Vivo (1968) (29)
- Stress changes in the femoral head due to porous ingrowth surface replacement arthroplasty. (1984) (29)
- The Otto Aufranc Award paper. New advances in the prevention, diagnosis, and cost effectiveness of venous thromboembolic disease in patients with total hip replacement. (1987) (29)
- Cemented revision for femoral osteolysis in cemented arthroplasties. Results in 29 hips after a mean 8.5-year follow-up. (1994) (28)
- Paget's disease involving the hip joint. (1971) (27)
- Radiation-blocking shields to localize periarticular radiation precisely for prevention of heterotopic bone formation around uncemented total hip arthroplasties. (1990) (27)
- Medial-displacement intertrochanteric osteotomy in the treatment of osteoarthritis of the hip. A long-term follow-up study. (1984) (27)
- Revision of the acetabular component without cement after a previous acetabular reconstruction with use of a bulk femoral head graft in patients who had congenital dislocation or dysplasia. A follow-up note. (1999) (27)
- Average 12-year outcome of a chrome-cobalt, beaded, bony ingrowth acetabular component. (1998) (27)
- The effect of a thin coating of polymethylmethacrylate on the torsional fatigue strength of the cement-metal interface. (1992) (26)
- Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film. (2007) (26)
- A finite element study of the effect of diametral interface gaps on the contact areas and pressures in uncemented cylindrical femoral total hip components. (1991) (26)
- Effect of improved cementing techniques on the longevity of fixation in revision cemented femoral arthroplasties. Average 8.8-year follow-up period. (1995) (26)
- Techniques for implementing an in vivo bone strain gage system. (1981) (25)
- Unrecognized femoral fractures during cementless total hip arthroplasty in the dog and their effect on bone ingrowth. (1992) (25)
- Options for primary femoral fixation in total hip arthroplasty. Cemented stems for all. (1997) (25)
- Alterations in femoral and acetabular bone strains immediately following cementless total hip arthroplasty: An in vitro canine study (1991) (24)
- Acetabular cement compactor. An experimental study of pressurization of cement in the acetabulum in total hip arthroplasty. (1983) (24)
- A preliminary report of the use of a cementless acetabular component with a cemented femoral component. (1989) (23)
- Influence of prophylaxis on proximal venous thrombus formation after total hip arthroplasty. (1992) (23)
- Porous-coated uncemented components in experimental total hip arthroplasty in dogs. Effect of plasma-sprayed calcium phosphate coatings on bone ingrowth. (1992) (23)
- Effects of Femoral Neck Length, Stem Size, and Body Weight on Strains in the Proximal Cement Mantle (2002) (23)
- A new approach for the Martell 3‐D method of measuring polyethylene wear without requiring the cross‐table lateral films (2005) (22)
- Bone ingrowth into a low-modulus composite plastic porous-coated canine femoral component. (1992) (22)
- Characteristics of the articular cartilage formed after intertrochanteric osteotomy. A case report. (1995) (21)
- Total joint replacement. (1977) (21)
- A stem design change to reduce peak cement strains at the tip of cemented total hip arthroplasty. (2000) (21)
- Reduced bone stress as predicted by composite beam theory correlates with cortical bone loss following cemented total hip arthroplasty (1999) (21)
- A new technique for removal of broken femoral stems in total hip replacement. A technical note. (1981) (21)
- The role of diagnostic and therapeutic angiography in trauma to the pelvis. (1980) (20)
- X‐ray tomography of feed‐to‐glass transition of simulated borosilicate waste glasses (2017) (20)
- Resultant loads and elastic modulus calibration of long bone cross sections. (1981) (20)
- Differential response to electrical stimulation: a distinction between induced osteogenesis in intact tibiae and the effect on fresh fracture defects in radii. (1977) (20)
- Failure of the cement-bone interface. (1995) (20)
- Comparison of diametral shrinkage of centrifuged and uncentrifuged Simplex P bone cement. (1995) (20)
- Advances in prevention of venous thromboembolic disease after elective hip surgery. (1990) (20)
- "The lysis threshold": an erroneous and perhaps misleading concept? (2003) (20)
- The effect of the addition of methylene blue on the fatigue strength of Simplex P bone-cement. (1992) (19)
- Extensive osteolysis behind an acetabular component that was well fixed with cement. A case report. (1993) (19)
- Isolated acetabular revision through the posterior approach: short-term results after revision of a recalled acetabular component. (2005) (18)
- Mycobacterium avium intracellulare infection of hip arthroplasties in an AIDS patient. (1994) (18)
- Traumatic disruption of cervical intervertebral disk from hyperextension injury. (1968) (18)
- The use of trans-vinylene formation in quantifying the spatial distribution of electron beam penetration in polyethylene. Single-sided, double-sided and shielded irradiation. (2003) (18)
- Techniques of extraction of well-fixed cemented and cementless implants in revision total hip arthroplasty. (1993) (17)
- Comparison of cerclage techniques using a hose clamp versus monofilament cerclage wire or cable. (1997) (17)
- The calcar replacement femoral component for total hip arthroplasty: design, uses and surgical technique. (1981) (16)
- Developments in diagnosis of the painful total hip replacement. (1993) (16)
- Loosening of cobalt chrome beads from a porous-coated acetabular component. A report of ten cases. (1988) (16)
- Transcatheter embolization for the control of wound hemorrhage following hip surgery. (1980) (16)
- The value of contrast arthrography in assessing loosening of symptomatic uncemented total hip components (2004) (16)
- Resection arthroplasty for nonseptic failure of total hip arthroplasty. (1982) (16)
- The correlation between minor or unrecognized developmental deformities and the development of osteoarthritis of the hip. (2009) (16)
- Evaluation of bone cement failure criteria with applications to the acetabular region. (1983) (16)
- Growth hormone: the effect on skeletal renewal in the adult dog I. Morphometric studies (2005) (16)
- Strength of cement-metal interfaces in fatigue: Comparison of smooth, porous and precoated specimens (1993) (15)
- Loosening of the femoral component of total hip replacement after plugging the femoral canal. (1982) (15)
- A double-blind study on the effects of a capacitively coupled electrical field on bone ingrowth into porous-surfaced canine total hip prostheses. (1990) (15)
- MOLD ARTHROPLASTY IN THE TREATMENT OF HIP FRACTURES COMPLICATED BY SEPSIS. (1965) (15)
- Strength of cement-metal interfaces in fatigue: comparison of smooth, porous and precoated specimens. (1994) (15)
- Growth hormone: The effect on skeletal renewal in the adult dog (2005) (15)
- Dissociation between the effect of bovine growth hormone in articular cartilage and in bone of the adult dog. (1978) (14)
- Effects of application of metal plates to bone. Comparison of a rigid with a flexible plate. (1980) (13)
- Comparative fatigue behavior of different bone cements. (1984) (13)
- Current status of noncemented hip implants. (1987) (13)
- The carcinogenesis of plastics used in orthopedic surgery. An assessment of the incidence in rats and the possible relevance to man. (1972) (13)
- Follow-up of intertrochanteric osteotomy of the hip during a 25-year period. (1998) (13)
- Calcification in Biological Systems. Edited by R. F. Sognnaes. Washington, D. C., American Association for the Advancement of Science, 1960. $9.75 (1961) (13)
- Stress fracture of the medial wall of the acetabulum adjacent to a cementless acetabular component. (2002) (13)
- In vitro evaluation of bonding of the cement‐metal interface of a total hip femoral component using ultrasound (1995) (13)
- Contemporary algorithms for evaluation of the painful total hip replacement. (1993) (12)
- Impedance phlebography: a correlation with lower limb venography in the diagnosis of deep vein thrombosis. (1973) (12)
- Comparison and optimization of three centrifugation systems for reducing porosity of Simplex P bone cement. (1989) (12)
- Effect of oral alendronate on net bone ingrowth into canine cementless total hips. (2005) (12)
- Polyethylene wear in cases using femoral stems of similar geometry, but different metals, porous layer, and modularity. (1998) (12)
- Erratum to ‘Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)’: [Biomaterials 20 (1999) 1463–1470] (2003) (12)
- Total hip replacement in the middle-aged patient. Contemporary cementing for fixation of the femoral component. (1993) (12)
- Biomechanics of cemented and cementless prostheses. (1992) (11)
- My first 50 years of orthopaedic surgery. (2001) (11)
- Technique to detect migration of femoral components of total hip arthroplasties on conventional radiographs. (1991) (11)
- Disseminated intravascular coagulation in patients undergoing orthopedic surgery. (1974) (10)
- Compression plating: experimental study of the effect on bone formation rates. (1973) (10)
- Total hip replacement for osteoarthritis secondary to congenital dysplasia or congenital dislocation of the hip (1978) (10)
- Assessment of the symmetry of bone strains in the proximal femoral medial cortex under load in bilateral pairs of cadaver femurs. (1997) (10)
- Cross-linked polyethylene: why the enthusiasm? (2001) (9)
- Bead loosening from a porous-coated acetabular component. A follow-up note. (1992) (9)
- Factors controlling optimal bone ingrowth of total hip replacement components. (1986) (9)
- Stimulation of bone formation in vivo by phosphate supplementation (1977) (9)
- A critical assessment of proximal macrotexturing on cemented femoral components. (2001) (9)
- Bone grafting for acetabular deficiency in association with total hip replacement. (1987) (8)
- The case for cementing all femoral components in total hip replacement. (1995) (8)
- Cemented revision for femoral failure. (1995) (8)
- Skeletal renewal and metabolic bone disease. (1969) (8)
- A new power tool for removal of methylmethacrylate from the femur. (1978) (8)
- Periprosthetic femoral osteolysis around an uncemented nonmodular Moore prosthesis. (1997) (8)
- Extensive exposure of the hip joint. (1973) (8)
- Elevated partial thromboplastin time as an indicator of hemorrhagic risk in postoperative patients on warfarin prophylaxis. (1988) (8)
- Modularity is unnecessary in primary femoral THA but has some advantages in primary acetabular THA. (1996) (8)
- THE ANISOTROPIC PROPERTIES OF TRABECULAR BONE (1980) (8)
- SEVEN TO TEN YEAR FOLLOW-UP OF HIGHLY CROSS-LINKED POLYETHYLENE LINERS IN TOTAL HIP ARTHROPLASTY (2010) (8)
- An electronic database for outcome studies that includes digital radiographs. (2001) (7)
- The effect of surface finish and of vertical ribs on the stability of a cemented femoral stem: an in vitro stair climbing test. (2006) (7)
- Greenfield vena caval filter for management of selected cases of venous thromboembolic disease following hip surgery. A report of five cases. (1986) (7)
- An Algorithm to Generate Synthetic 3D Microstructures from 2D Exemplars (2020) (7)
- An integrated solution to acetabular revision surgery. (2006) (7)
- One-staged exchange arthroplasty for septic total hip replacement. (1986) (7)
- Microscopic method of measuring increases in cortical bone volume and mass (1971) (6)
- In vivo intracortical loading histories calculated from bone strain telemetry (1982) (6)
- Mode of loosening of matt-finished femoral stems in primary total hip replacement. (2002) (6)
- A look at the prosthesis-cartilage interface: design of a hip prosthesis containing pressure transducers. (1974) (6)
- Qualitative analysis of polyethylene particles extracted from bovine serum used in a hip simulator (1998) (6)
- A composite plug for occluding the femoral canal prior to cementing a total hip femoral component. (1994) (6)
- Development of a Model for Testing Third Body Wear of UHMWPE Acetabular Components (2004) (5)
- Average 12-year outcome of a chrome-cobalt, beaded, bony ingrowth acetabular component. (1998) (5)
- The Role of Crosslinked Polyethylene in Reducing Aggregated Costs of Total Hip Arthroplasty in the United States. (2019) (5)
- Polished vs rough femoral components in grade A and grade C-2 cement mantles. (2006) (5)
- Arterial embolization for radical tumor resection. (1977) (5)
- Removal of broken stems of total joint components by a new method: drilling, undercutting, and extracting without damage to bone. (1981) (5)
- Surgical management of arthritis of the hip. (1971) (4)
- Why have we left Charnley low friction arthroplasty? (1993) (4)
- A "second generation" total hip replacement. (1973) (4)
- Total hip replacement: "cement versus cementless" resolution. (1994) (4)
- The case for cemented fixation of the femur in every patient. (1994) (4)
- In vivo comparison of traditional vs. highly crosslinked polyethylene wear (2004) (4)
- Last decade in THA: unsettling and disappointing. (2014) (4)
- Porous hemispherical sockets: when round is right. (2001) (4)
- Effects of pressurization on the intrusion and mechanical properties of PMMA (1980) (4)
- Case records of the Massachusetts General Hospital. Weekly clinicopathological exercises. Case 34-1990. A 74-year-old man with a failed right-hip replacement, constant pain centered in the right hip, and an osteolytic lesion in the right acetabulum. (1990) (4)
- Subclinical osteomyelitis of the femoral head. Two cases illustrating a special problem in the use of total hip replacement. (1972) (3)
- Quantitative comparison of volumetric wear using 22MM, 26MM and 32MM femoral heads: A hip simulator study (1998) (3)
- Patterns of Osteolysis in Two Different Cementless Total Hip Arthroplasties (1997) (3)
- OPTIMUM FIXATION OF BONE CEMENT IN TOTAL HIP REPLACEMENT (1979) (3)
- Radio-anatomical study of the human femur (1982) (3)
- Case report 816 (1993) (3)
- Handbook of Orthopaedic Surgery. Ed. 5. A. R. Shands, Jr., M.D. St. Louis, The C. V. Mosby Company, 1957. $9.75 (1959) (3)
- Bone cement as a seal protecting the femur from the ingress of particulate debris and femoral osteolysis. (1996) (3)
- Advantages of metal-backed acetabular components for a total hip replacement: a clinical assessment with a minimum 5-year follow-up. (1983) (3)
- Sinking prostheses. (1966) (3)
- Bulk versus morselized bone graft in acetabular revision total hip replacement. (1993) (3)
- The relationship of intravascular coagulation and fibrinolysis to venous thrombosis following total hip replacement. (1978) (3)
- Direct reimplantation of total hip replacements in septic hips in the adult. (1982) (3)
- Advances in total hip reconstruction. (1991) (3)
- Reverse Skeletal Traction for Instability Following Revision Total Hip Arthroplasty: A Report of Two Cases (1988) (3)
- A New Method to Determine the Locus of Radiation Damage in Retrieved Ultra-High Molecular Weight Polyethylene (UHMWPE) Components (1998) (3)
- Dynamic frictional comparison of different femoral head sizes and different lubricants (1998) (3)
- RADIOSTEREOMETRIC ANALYSIS (RSA) STUDIES AT MASSACHUSETTS GENERAL HOSPITAL (2003) (2)
- Effect of cross-linking on the wear beha vior of ultra high molecular weight polyethylene (UHMWPE) used in total joint replacements (1998) (2)
- Aspirin Prophylaxis Against Thromboembolic Disease (1977) (2)
- To reduce routine computed tomographic angiography for thoracic aortic injury assessment in level II blunt trauma patients using three mediastinal signs on the initial chest radiograph: a preliminary report (2018) (2)
- Accuracy Enchancement of In-Vivo Bone Strain Measurements and Analysis (1982) (2)
- The three revolutions in acetabular revision surgery for total hip replacement: 1. Definite and 2. Probable. (2003) (2)
- Anisotropic oxidation and radial cracks in retrieved acetabular components (1998) (2)
- Endosteal Osteolysis Around Well-Fixed Porous-Coated Cementless Femoral Components (1992) (2)
- JOINT-REPLACEMENT SURGERY (1991) (2)
- A hip simulator evaluation of different forms of highly cross-linked polyethylene (1998) (2)
- Validation of Digital Radiography, for use with Radiostereometric Analysis (RSA) using a Dynamic Phantom Wear Model (2002) (2)
- A 6.5-YEAR FOLLOW-UP STUDY (1993) (2)
- LOW-DOSE HEPARIN IN TOTAL HIP REPLACEMENT (1976) (2)
- Insertion of a prosthetic hip into a total hip allograft. Case report. (1990) (2)
- Role of intertrochanteric osteotomy in the treatment of arthritis of the hip. (1969) (2)
- Long stem femoral components for total hip replacement. (1978) (2)
- Hybrid revision total hip arthroplasty: a 7-year follow-up study. (2001) (2)
- Hybrid tota hip arthroplasty (1989) (2)
- Controlled in vivo inhibition of bone formation (1965) (2)
- The femoral stent. Surgical technique for a new method of cementing the femoral component in the presence of a large cortical defect. (1995) (1)
- A new splint for balanced suspension. (1970) (1)
- Behavior of cartilage layers subjected to periodic dynamic regimes (1982) (1)
- Case report 816: Rapid acceleration of osteolysis from loose cemented total hip replacement. (1993) (1)
- The Importance of the Thickness of the Femoral Cement Mantle (2003) (1)
- Mould Arthroplasty in the Treatment of Septic Arthritis of the Hip [Abstract] (1969) (1)
- Analytical macrogeometry representation and congruency of the human hip joint (1981) (1)
- Report on basic research activities in orthopaedic surgery in Great Britain. (1966) (1)
- The accuracy of the in vivo diagnosis of deep vein thrombosis in patients with prior venous thromboembolic disease or severe varicose veins. (1981) (1)
- In vitro comparison of hip wear of marathon and durasul using both 32 and 38-mm head diametersy (2004) (1)
- Accuracy enhancement of in-vivo bone strain measurements and analysis. (1982) (1)
- Surgical approach and technique of cup arthroplasty. (1969) (1)
- Paper #3 Matched pair analysis of cemented and uncemented acetabular components in primary total hip arthroplasty at ten year follow-up (1999) (1)
- Patellectomy and fascial grafting in certain cases of long standing disruption of the quadriceps mechanism; a case report and review of the literature. (1957) (1)
- GEOMETRY OF THE HUMAN HIP JOINT (1980) (1)
- A MULTI-CENTER STUDY OF THE MID-TERM WEAR RESULTS OF HIGHLY CROSS-LINKED POLYETHYLENE THR COMPONENTS (2011) (1)
- The lessons of acetabular component fixation. (1995) (1)
- Power instrumentation for cup arthroplasty. (1970) (1)
- Autografting and allografting in aseptic failure of total hip replacement. (1984) (1)
- DEVELOPMENT OF A PATELLO-FEMORAL GAIT WEAR SIMULATION (2004) (1)
- Altered stress fields created by the application of different fracture plates to the canine femur (1981) (1)
- VANISHING BONE: HOW TO ATTACK AN ENIGMA. LESSONS LEARNED FROM THE PERIPROSTHETIC OSTEOLYSIS CRISIS AND ITS CURE (2018) (0)
- A new technique of crosslinking to dramatically improve the wear resistance of ultra high molecular weight polyethylene (1998) (0)
- Quantitative synovial joint geometry and load distribution (1981) (0)
- Hip challenges: what would you do? (1995) (0)
- Book ReviewHandbook of Orthopaedic Surgery. (1967) (0)
- Local variations in the pressures in the human hip joint (1981) (0)
- The hip : proceedigns of the ... open scientific meeting of the Hip Society ... (1973) (0)
- [The influence of direct electric current on bone formation (author's transl)]. (1979) (0)
- PRESIDENTIAL GUEST ADDRESS Conquest of a Worldwide Human Disease (2004) (0)
- MAJOR ACETABULAR BONE DEFICIENCY USING STRUCFURAL FEMORAL HEAD ALLOGRAFI'S (1990) (0)
- Letter: Low-dose heparin and the prevention of venous thromboembolic disease. (1976) (0)
- Total hip replacement in the congenitally dysplastic hip (1995) (0)
- Highly Cross-linked Polyethylene–Metal Articulations as an Alternative to Ceramic on Ceramic for Total Hip Replacement Surgery (2006) (0)
- Managing degenerative arthritis of the hip. (1969) (0)
- THE HISTOLOGYTHE RADIOLUCENT LINE (1992) (0)
- Book ReviewAcrylic Cement in Orthopaedic Surgery. (1971) (0)
- Modular type transplant and adhesive method of element of this transplant (1992) (0)
- HIGHLY CROSS-LINKED POLYETHYLENE FOR THE PATELLA: AN IN-VITRO STUDY USING NEWLY DEVELOPMENT TEST METHODS TO COMPARE ELECTRON BEAM MELTED AND CONVENTIONAL POLYETHYLENE (2004) (0)
- RADIOGRAPHIC EVALUATION OF POLYETHYLENE WEAR IN ACETABULAR COMPONENTS: COMPARISON OF 2D AND 3D MEASUREMENT TECHNIQUES WITH ASSESSMENT OF INTEROBSERVER VARIATION (2003) (0)
- [Electric stimulation in osteogenesis. Studies of the cathode]. (1978) (0)
- Fatigue of acrylic bone cement—The influence of strain range and mean strain (1983) (0)
- THE INFLUENCE OF LOAD PARAMETERS ON PRESSURE DISTRIBUTIONS IN THE HUMAN HIP JOINT (1980) (0)
- Paper #11 THA following previous femoral osteotomy: A 15 year follow up study (1996) (0)
- Cementless acetabular components in primary total hip arthroplasty at ten years (1998) (0)
- A Single-plane Fluoroscopic RSA Method for Joint Kinematics : An Assessment of Bias and Precision (2005) (0)
- Vastus-Psoas release for acetabular exposure in revision hip surgery. (1997) (0)
- Kinematic joint measurement RSA flouroscopy (2004) (0)
- Closed pressurization of medullary cement in total hip replacement (1980) (0)
- A MATHEMATICAL CONSISTENCY CHECK FOR IN VIVO STRAIN MEASUREMENTS (1981) (0)
- Drilling device and guiding method for surgical operation (1989) (0)
- Answer to Dr. Frost's letter to the editor (2005) (0)
- A SUMMING UP: WISDOM COMES WITH TIME AND AGE (2018) (0)
- Monopolar restrictive acetabularteil (2001) (0)
- The high hip center : Revision Total Hip Arthroplasty (2004) (0)
- Chapin Oration: Detection and prevention of thromboembolic disease. (1976) (0)
- Improving UHMWPE Using Electron Beam Irradiation (2005) (0)
- Paper #19 Patterns traced by femoral head on acetabulum during physiologic conditions (1996) (0)
- A 69-year-old woman with thigh pain 21 years after total hip arthroplasty. (1995) (0)
- Borderline indications for use of cement in total joint replacements. (1992) (0)
- 25 Power Instrumentation for Cup Arthroplasty (1970) (0)
- The first 51 years of total hip arthroplasty: now, a surprising new era (2014) (0)
- Kinematic joint measurement using single-plane RSA (2004) (0)
- A new paradigm, a follow-up letter to the editor of the journal of arthroplasty. (2014) (0)
- Letter to the Editor: Editor’s Spotlight/Take 5: CT Pulmonary Angiography After Total Joint Arthroplasty: Overdiagnosis and Iatrogenic Harm? (2013) (0)
- [Time study of the reaction of non-fractured bone under osteosynthesis plates. Effect on bone of removal of the material]. (1978) (0)
- The value of preoperative aspiration in revision total hip replacement surgery (1993) (0)
- Measurement and Simulation of Thermal Conductivity of Hafnium-Aluminum Thermal Neutron Absorber Material (2016) (0)
- 24 A New Splint for Balanced Suspension (1970) (0)
- Development of a Knee Phantom for the Evaluation of Methods for Measuring Knee Joint Kinematics (2004) (0)
- Alternative Bearing Surfaces: Crosslinked Polyethylenes for Total Hip Replacement. A Review (2003) (0)
- Hip challenges: what would you do? (1998) (0)
- A large collar in hip replacement. (1996) (0)
- Prosthetic devices of ultra-high-molecular-weight polyethylene treated by fusion and radiation. (1997) (0)
- High placement of the uncemented acetabular component in revision surgery: Results after an average of 10.2 years (1998) (0)
- Association between hospital and surgeon procedure volume and outcomes of orthopaedic surgery: Caveats for interpretation of data and policy applications [3] (multiple letters) (2002) (0)
- The acetabular cement compactor: An improvement in cementing technique in total hip replacement (1980) (0)
- Development of a Marker-less Radiostereometric Analysis (RSA) Method for Use in Measuring Polyethyene Wear : A Comparative Study (2006) (0)
- Fatigue Acetabular Cup UHMWPE WEAR AND HIGH CYCLE FATIGUE OF A HIGHLY CROSSLINKED UHMWPE (1999) (0)
- BONE-CEMENT INTERFACE PRESSURES IN DIFFERENT FEMORAL COMPONENTS OF TOTAL HIP REPLACEMENT (1979) (0)
- Drill alignment apparatus for osteoplastic surgery (1989) (0)
- Dr. Harris' response to Dr. Cameron (1996) (0)
- BEYOND VANISHING BONE (2018) (0)
This paper list is powered by the following services:
What Schools Are Affiliated With W. H. William H. Harris?
W. H. William H. Harris is affiliated with the following schools: